Model | 6805 | 6810 | 6820 | 6830 | 6840 |
INPUT |
Phase | 1 phase |
Voltage | 115/230Vac ± 15% | 230Vac ± 15% |
Frequency | 47-63Hz |
OUTPUT |
Max. Power | 500VA | 1000VA | 2000VA | 3000VA | 4000VA |
Max Current(r.m.s) | 0-150V | 4.2A | 8.4A | 16.8A | 25.2A | 33.6A |
0-300V | 2.1A | 4.2A | 8.4A | 12.6A | 16.8A |
Max Current(r.m.s) Opt. 0-600 V | 0-300V | 2.1A | 4.2A | 8.4A | 12.6A | 16.8A |
0-600V | 1.05A | 2.1A | 4.2A | 6.3A | 8.4A |
Phase | 1 phase / 2W |
Total Harmonic Distortation (T.H.D) | <=0.5% at 45-500Hz (Resistive Load) |
Crest Factor | >= 4 |
Line Regulation | ±0.1V |
Load Regulation | <=0.5% (Resistive Load) |
Response Time | < 100µS |
SETTING |
Voltage | Range | 0-150V / 0-300V Selectable or 0-300V / 0-600V Selectable (Option 0 -600V) |
Resolution | 0.1V |
Accuracy | ±(0.5% of setting 2 counts) |
Frequency | Range | 45-500Hz |
Resolution | 0.1Hz at 45.0-99.9Hz , 1Hz at 100-500Hz |
Accuracy | ±0.02% of setting |
Frequency (Option 45Hz - 1KHz) | Range | 45-1000Hz |
Resolution | 0.1Hz at 45.0-99.9Hz , 1Hz at 100-1000Hz |
Accuracy | ±0.02% of setting |
MEASUREMENT |
Frequency | Range | 45.0Hz - 500.0Hz 501.0Hz - 1000Hz (Opt.614) |
Resolution | 0.1Hz |
Accuracy | ±0.1Hz at 45.0 - 500.0Hz ±0.5Hz at 501.0 - 1000Hz |
Voltage | Range | 0.0-300.0V / 0.0-600.0V |
Resolution | 0.1V |
Accuracy | ± (0.5% of reading 2 counts) for 0-300V ± (0.5% of reading 4 counts) for 0-600V |
Current(r.m.s) | Range | L | 0.000-3.500A |
H | 3.00-35.00A |
Resolution | L | 0.001A |
H | 0.01A |
Accuracy | L | ± (0.5% of reading 5 counts) |
H | ± (0.5% of reading 3 counts) |
Power | Range | L | 0.0-350.0W |
H | 300-4000W |
Resolution | L | 0.1W |
H | 1W |
Accuracy | L | ± (0.6% of reading 5 counts) |
H | ± (0.6% of reading 2 counts) |
Power Factor | Range | 0.000-1.000 |
Resolution | W / VA ,Calculated and displayed to three significant digits |
Accuracy |
GENERAL |
Low Range Meter (for 6805/ 6810 Option) | Range : 2.0mA - 350.0mA / 0.20 - 35.00W Resolution : 0.1mA / 0.01W Accuracy : ± (0.6% of reading 5 counts). |
Remote Input Signal Interface (Option) | Test, Reset, Recall memory 1 through 7 |
Remote Output Signal | Fail ,Test-in Process |
Over Current Fold Back | On/Off , Setting On when output current over setting A-Hi value it will fold back output voltage to keep constant output current is setting A-Hi value. |
Protection | OCP, OTP ,OVP and Alarm |
Safety | TUV/GS pending |
Dimension(W x H x D) mm | 430 x 89 x 400,2U | 430 x 89 x 560,2U | 430 x 267 x 650,6U | 430 x 667 x 650,15U | 430 x 667 x 650,15U |
Net Weight | 25Kg | 36Kg | 90Kg | 165Kg | 192Kg |
Operation Environment | 0-40°C / 20-80%RH |