General specifications |
Switching element function | NAMUR, NC |
Rated operating distance | 15 mm |
Installation | not embeddable |
Output polarity | NAMUR |
Assured operating distance | 0 ... 12.15 mm |
Reduction factor rAl | 0.4 |
Reduction factor rCu | 0.35 |
Reduction factor r303 | 0.7 |
Nominal ratings |
Nominal voltage | 8 V DC |
Switching frequency | 0 ... 150 Hz |
Hysteresis | 5 ... 15 typ. 5 % |
Reverse polarity protected | reverse polarity protected |
Short-circuit protection | yes |
Current consumption | |
| Measuring plate not detected | min. 2.2 mA |
| Measuring plate detected | ≤ 1 mA |
Indication of the switching state | all direction LED, yellow |
Compliance with standards and directives |
Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
Approvals and certificates |
FM approval | |
| Control drawing | 116-0165F |
UL approval | cULus Listed, General Purpose |
CSA approval | cCSAus Listed, General Purpose |
CCC approval | Products with a maximum operating voltage of ≤36 V do not bear a CCC marking because they do not require approval. |
Ambient conditions |
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
Mechanical specifications |
Connection type | cable PVC , 2 m |
Core cross-section | 0.75 mm2 |
Housing material | Stainless steel |
Sensing face | PBT |
Protection degree | IP67 |
General information |
Use in the hazardous area | see instruction manuals |
| Category | 1G; 2G; 3G; 1D; 3D |