Specification | | |
Type | E308 | E309 |
Ac supply version | 240Vac/120Vac (+5/-20%), 50/60Hz 10VA | 240Vac/120Vac (+10/-20%), 50/60Hz 10VA |
Compatible with | Most full bridge strain gauge transducers Most amplified transducers from any manufacturer | Any standard RDP LVDT (without integral electronics). Most LVDTs from any manufacturer. |
Number of digits | 4 �, red LED (11mm) | 4 �, red LED (11mm) |
Display update rate | 2.5Hz | 2.5Hz |
Transducer excitation | 1.2V to 15V & -15V, 60mA | 5V, 5kHz (1kHz to 10kHz with component change), 100mA |
Signal input range | 5mV to 90V | 50mV to 20V |
Output details | ±10V / 4-20mA (loop resistance 0 Ohms to 500 Ohms) | ±10V / 4-20mA (loop resistance 0 Ohms to 500 Ohms) |
Electrical output bandwidth | 0 to 150Hz (3Hz with filter turned on) | 0 to 300Hz |
Input impedance | 2M Ohms | 100k Ohms |
Linearity error | ±0.02% F.S. typical | ±0.1% F.S. |
Output ripple (peak-to-peak) | 10mV typical / 30uA typical | 5mV typical / 10uA typical |
Temperature coefficient (zero) | ±0.01% F.S. /癈 (typical) | ±0.01% F.S. /癈 (typical) |
Temperature coefficient (span) | ±0.01% F.S. /癈 (typical) | ±0.01% F.S. /癈 (typical) |
Limit trips | Number of channels | 2 | 2 |
Operation time | 5ms | 5ms |
Contact rating | 24Vdc (1A) / 120Vac (0.3A) | 24Vdc (1A) / 120Vac (0.3A) |
Operating temperature range | 0癈 to 50癈 | 0癈 to 55癈 |
Total weight | 1.3kg | 1.3kg |