规格(Item No) | CA-641P | CA-642PB |
显示范围 | Total 6 Digit preset 4 Digit |
Display Range |
设定范围 | 1 set 1~9999 | 2 Sets1 set1~9999 |
Setting Range | pre warn 1~99 |
字型尺寸 | Ttal LED0.4"(orang)Preset LED0.3"(Green) |
Character Height |
计数输入 | 有接点输入无接点输入 |
Input Signal Mode | Contact input:25Hznon-contact input:3KHz(on-off ratio 1:1) |
输出方式 | 2 sets Relay output (la,b AC 25OV/) |
Output System |
输出时间 | 0.1~9.9 seconds(variable) |
Output Hold time |
复归方式 | Extemal,Manual,Auto Reset |
Reset Syetem |
输入信号 | NPN,open collector |
Input level |
停电记忆 | EEPROM memory keep ten years |
Power Failure Memory |
信号电源 | DC12v?5%Max electric current capacity 100mA |
DC Out for Sensor |
电源电压 | AC 110v/220v?15PHz/60Hz |
Power Supply |
消耗电力 | 5.5VA |
Power Consumption |
耐温湿度 | —10℃?50℃35%~85%RH |
Operating Temperatur Humidity |
尺寸规格 | 72mm*72mm*145mm(版面开孔Mounting flush dimension:68mm*68mm) |
External Dimensions |
Switch Setup | 一、SW1输入频率Response Time Swith |
SW1-Hi:信号无滤波电容,频率可达3KHz |
SW1-Md:信号有滤波电容,频率可达300Hz |
SW1-Lo:信号有滤波电容,频率可达25Hz |
二、SW2:N.R.C. |
1.:手动(MANUAL),SW2-3 ON计数值等于设定值时RELAY ON;计数继续上数到手动或 |
外部复归,RELAY1才OOF,计数值归零。 |
2.:回归(RETURU)计数值等于设定值时RELAY ON;计数继续上数,待T时间后(面板Timer |
调整)RELAY Return(复归)计数器值归零 | | |
3. ? C:继续(CONTNUE),SW2-1ON计数值等于设定值RELAY 1 ON,计数值立即归零后 |
再数继续上数.待T时间后RELAY才会OOF. | |
4.? SW2-4 OFF:上排Display和下排Display同为同步计数. |
Both uper and lower display are summing type. |
SW2-4 ON:下排Display计数至设定值时上排Display累计计数才加1.注:改变技术模式后,必须 |
关掉电源重新开机. |