ridge power supply | DC10 V±0.3 V within 120 mA (Changeable to DC2.5 V or DC5 V) with remote sensing function |
Input range | F.S. setting can be available at the input from 0.3 mV/V to 3 mV/V. (when bridge power supply is DC10 V) |
Zero adjustment range | 0 mV/V ~ 2.4 mV/V |
Non-linearity | 0.01 %F.S. |
Temperature coefficient | Zero point ±0.2 μV/°C (Input conversion) Sensitivity ±0.001 5 %F.S./°C |
Analog filter | 1 Hz on bessel characteristics |
Load display | Display of gross weight or flow rate value |
Display of setting | SV value and PV value |
Display range | 0 ~ 99 999 |
Display of operation status | ZERO, MA/SL, RE/LO, AUTO, VOLU., SUPPLY |
Display | 128 x 64 dots liquid crystal display (with back light LED type) |
Display times | 2 times/s |
Condition display | RUN, ALARM (LEDlight on) |
External control output | Signal of multiplication(pulse output), Signal of powder request, Alarm of upper limit, Alarm of lower limit, Alarm of flow rate declination, Out of control, RUN |
External control input | Start control, Signal of supplied powder, Signal of REMOTE MODE, Reset the multiplication |
Serial interface output for transmitting the flow rate value | Serial interface with 2 wires method |
Analog output for inverter control | Output 4 mA ~ 20 mA (Load resistance 510 Ω or less) Accuracy 0.05 %F.S. (Resolution 1/30 000) with scaling function |
Analog output for transmitting the flow rate value | Output 4 mA ~ 20 mA (Load resistance 510 Ω or less) Accuracy 0.05 %F.S. (Resolution 1/30 000) with scaling function |
Analog input for receiving the flow rate value | Input 4 mA ~ 20 mA (Input resistance 100 Ω) Accuracy 0.05 %F.S. (Resolution 1/30 000) with scaling function |
Operating temp./humidity range | Temperature 0 °C ~ 50 °C, Humidity 85 %RH or less (Non condensing) |
Power supply voltage | AC100 V (AC85 V ~ AC100 V) 50/60 Hz |
Power consumption | Approx. 19 VA |
Outline dimensions(WxHxD) | 192 mm x 96 mm x 175 mm (excludes protruding parts) |