美国VWR台式高压灭菌器
Tabletop Autoclaves, Tuttnauer*/Brinkmann
台式高压灭菌器For sterilization of equipment, materials, or liquids. Autoclaves permit fast, safe, dependable, convenient sterilization, without the need for special plumbing or venting. High grade 316L stainless steel sterilization chambers resist corrosion. Fast exhaust option reduces cycle time for solid goods; slow exhaust option releases chamber pressure slowly and prevents boiling over of liquids. Continuous pressure purge eliminates cold air pockets and ensures uniform sterilization. Large 3.25L water reservoir permits users to control the purity of the sterilizing steam and reduces frequency of fill-ups. Drying cycle prevents rusting of valuable instruments and dries absorbent materials. Low water level protection prevents damage to heating elements. Heat-insulated, double-locking door safeguards against accidental burns. Dead bolt lock prevents door from being opened while chamber is pressurized.3.25l水库允许用户控制灭菌蒸汽纯度降低填满频率。干燥周期,防止生锈和干燥吸湿材料贵重仪器。低水位保护防止加热元件的损坏。热绝缘,双锁的门,防止意外烧伤。闩锁防止门被打开,室加压
M Models: Economical, mechanical models have analog controls and analog display of pressure and temperature. They come with a 60 minute timer and feature temperature selection from 100 to 134°C (212 to 273°F)m模型:经济,机械模型模拟控制和压力和温度的模拟显示。他们有一个60分钟的计时器和特征温度的选择,从100到134°C(212至273°F)。.
E Models: Electronically controlled models feature microprocessor control with digital display of operating parameters. Four fully adjustable, one-button programs provide easy, reproducible runs for wrapped and unwrapped items as well as liquids. User sets and stores operating parameters of temperature (105 to 137°C, 221 to 279°F), sterilization time (0 to 59 minutes), pressure (0 to 40psi), and drying time (0 to 99 minutes). User also sets and stores units of °C or °F and psi or bar. A sensor prevents operation until the door is securely closed. In-line filters protect all pressure valves. A low-water signal indicates the reservior needs to be filled.
EP Models: These units include all the features of E models plus a built-in printer. The printer validates each sterilization cycle by recording elapsed sterilization and drying time, real time and real date, temperature, pressure, cycle number, and program type. Sterilization temperature and pressure are printed every minute. Printer provides a summary at the end of each cycle with all documentation. If an error or interruption occurs at any point during the cycle, the event and cause of cycle failure will be documented on the printout.
Ordering Information: Supplied with one-year manufacturer's warranty on parts, instruction manual, stainless steel trays, drain tube, and 1.8m (6') line cord with three-wire plug. Selected models come with a stand.
UL listed and CSA certified; ASME stamped.
Analog Control and Display