srs RGA Series-Up to 300 amu gas analyzers
主要指标与说明The 100, 200 and 300 amu residual gas analyzers from SRS offer exceptional performance and value. These RGA's provide detailed gas analysis of vacuum systems at about half the price of competitive models. Each RGA system comes complete with a quadrupole probe, electronics control unit (ECU), and a real-time Windows software package that is used for data acquisition and analysis, as well as probe control.RGA Series Residual Gas Analyzers100, 200 and 300 amu systemsBetter than 1 amu resolution6 orders of magnitude dynamic range in a single scan5 x 10-14 Torr detection limitRGA Windows softwareRS-232 and Ethernet interfaces
RGA Series Residual Gas AnalyzersThe 100, 200 and 300 amu residual gas analyzers from SRS offer exceptional performance and value. These RGA's provide detailed gas analysis of vacuum systems at about half the price of competitive models. Each RGA system comes complete with a quadrupole probe, electronics control unit (ECU), and a real-time Windows software package that is used for data acquisition and analysis, as well as probe control.Rugged Probe DesignThe probe consists of an ionizer, quadrupole mass filter and a detector. The simple design has a small number of parts which minimizes outgassing and reduces the chances of introducing impurities into your vacuum system. The probe assembly is rugged and mounts onto a standard 2 ? inch CF flange. It is covered with a stainless steel tube with the exception of the ionizer which requires just 2 ? inches of clearance in your vacuum system-about that of a standard ion gauge. The probe is designed using self-aligning parts so it can easily be reassembled after cleaning pact Electronics Control UnitThe densely packed ECU contains all the necessary electronics for controlling the RGA head. It is powered by either an external +24 VDC (2.5 A) power supply or an optional, built-in power module which plugs into an AC outlet. LED indicators provide instant feedback on the status of the electron multiplier, filament, electronics system and the probe. The ECU can easily be removed from the probe for high temperature bakeouts.Unique Filament DesignA long-life, dual thoriated-iridium (ThO2/Ir) filament is used for electron emission. Dual ThO2/Ir filaments last much longer than single filaments, maximizing the time between filament replacement. Unlike other designs, SRS filaments can be replaced by the user in a matter of minutes.Continuous Dynode Electron MultiplierA Faraday cup detector is standard with SRS RGA systems which allows partial pressure measurements from 10-5 to 5 × 10-11 Torr. For increased sensitivity and faster scan rates, an optional electron multiplier is offered that detects partial pressures down to 5 × 10-14 Torr. This state-of-the-art macro multi-channel continuous-dynode electron multiplier (CDEM) offers increased longevity and stability and can also be replaced by the user-a first for RGAs!Useful FeaturesAll RGAs have a built-in degassing feature. Using electron impact desorption, the ion source is thoroughly cleaned, greatly reducing the ionizer's contribution to background noise.A firmware driven filament protection feature constantly monitors (675 Hz) for over pressure. If over pressure is detected, the filament is immediay shut off, preserving its life.A unique temperature-compensated, logarithmic electrometer detects ion current from 10-7 to 10-15 Amps in a single scan with better than 2 % precision. This huge dynamic range means you can make measurements of small and large gas concentrations simultaneously.Complete ProgrammabilityCommunication with computers is made via the RS-232 interface. Analog and histogram (bar) scans, leak detection and probe parameters are all controlled and monitored through a high-level command set. This allows easy integration into existing programs.
RGA Windows SoftwareAnalog modePressure vs. timeLibrary modeThe RGA systems are supported with a real-time Windows software package that runs on PCs. The intuitive graphical user interface allows measurements to be made quickly and easily. The program is fully interactive, giving the user complete control of the graphical display. Screens can be split for dual-mode operation, scales can be set to linear or log format, and data can be scaled manually or automatically. Data is captured and displayed in real-time or scheduled for acquisition at a given time interval for long-term data logging. Features include user-selectable units (Torr, mbar, Pa and A), programmable audio and visual alarms, and comprehensive on-line help.The software also allows complete RGA head control with easy mass scale tuning, sensitivity calibration, ionizer setup, and electron multiplier gain adjustment. For further analysis, data files can be saved in ASCII format for easy transfer into spreadsheets. Graphic images can be saved as META files or copied to the clipboard for importing directly into other Windows programs. The software also provides password protection for locking out head parameters so that casual users can′t alter important settings. A LabVIEW driver is also available on the SRS website.An optional stand-alone monitor (PPM100) can be used to control the RGA without a host computer.Multi-Head OperationThe software supports multiple head operation when more than one RGA is needed. Up to eight ECUs can be monitored from the software.Performance and ValueThe SRS family of RGAs is ideal for applications involving gas analysis, leak detection, and vacuum processing. We offer 100, 200 and 300 amu systems with supporting Windows software and options that include an electron multiplier and a built-in power module for AC line operation. RGA Series Residual Gas AnalyzersOperationalMass range RGA100 1 to 100 amu RGA200 1 to 200 amu RGA300 1 to 300 amuMass filter type QuadrupoleDetector type Faraday cup (FC)-standard, electron multiplier (EM)-optionalResolution Better than 0.5 amu @ 10 % peak height (per AVS std. 2.3). Adjustable to constant peak width throughout the mass range.Sensitivity (A/Torr) 2 × 10-4 (FC), <200 (EM). User adjustable throughout high voltage range. Measured with N2 @ 28 amu with 1 amu full peak width, 10 % height, 70 eV electron energy, 12 eV ion energy, and 1 mA electron emission current.Minimum detectable partial pressure 5 × 10-11 Torr (FC). 5 × 10-14 Torr (EM). Measured with N2 @ 28 amu with 1 amu full peak width, 10 % height, 70 eV electron energy , 12 eV ion energy, and 1 mA electron emission current.Operating pressure 10-4 Torr to UHV (FC)10-6 Torr to UHV (EM)Max. operating temp. 70 °CBakeout temperature 300 °C (without ECU)
IonizerDesign Open ion source, cylindrical symmetry, electron impact ionization.Material SS304 constructionFilament Thoriated-iridium (dual) with firmware protection. Built-in 1 to 10 W degas ramp-up. Field replaceable.Electron energy 25 to 105 V, programmableIon energy 8 or 12 V, programmableFocus voltage 0 to 150 V, programmableElectron emission current 0 to 3.5 mA, programmableGeneralProbe dimension 8.75" from flange face to top of ionizerProbe insertion 2.0"Probe mounting flange 2.75" CFMinimum tube I.D. 1.375"ECU dimensions 9.1" ×4.1" × 3.1" (WHL) Easily separated from the probe for bakeout.LED indicators Power ON/OFF, filament ON/OFF, degas ON/OFF, electron multiplier ON/OFF, RS-232 Busy, Error, Overpressure, Burnt Filament.Warm-up time Mass stability ±0.1 amu after 30 minutesComputer interface RS-232C, 28,800 baud with high-level command setSoftware Windows based applicationPower requirement 24 VDC @ 2.5 amps. Male DB9 connector. Optional 110/120/220/240 VAC adapter.Weight 6 lbs.Warranty One year parts and labor on defects in materials and workmanship
Agilent 83497A 光电时钟恢复模块
Agilent 8157A 光衰减仪
Agilent 81637B 快速功率计
Agilent 34570A 数字万用表
Agilent 44476A 微波复用器模块
Agilent 70004A 光谱分析仪
Agilent 81000FI 光纤连接器
Agilent 81002FF 积分球
Agilent 81521B 光功率计探头
Agilent 81524A 光功率探头
Agilent 8152 大功率光学探头
Agilent 81533A 接口模块
Agilent 81533B 接口模块
Agilent 81536A 光功率计传感插件
Agilent 81560A 可变光衰减器
Agilent 81567A 可变光衰减器模块
Agilent 8156A 光衰减器
Agilent 81578A可变光衰减器模块
Agilent 81610A回损测试模块
Agilent 81619A 光功率模块
Agilent 81624A 光学探头
Agilent 8162 光功率探头
Agilent 81633A 分布式反馈(DFB)激光器
Agilent 8163 双光功率传感器
Agilent 8163A光功率计主机
Agilent 8163B 光功率计
Agilent 8164A 光波测量系统主机
Agilent 81650A 单法布里-珀罗激光源
Agilent 81651A 光源模块
Agilent 81654A 法布里-珀罗激光源
Agilent 81662A 分布式反馈(DFB)激光器
Agilent 8168E 可调谐激光源
Agilent 83440D光波转换器
Agilent 83480A 数字通信分析仪
Agilent 83483A 双通道电模块
Agilent 83486A 光电模块
Agilent 83487A 光电模块
Agilent 83492A 多模时钟模块
Agilent 83493A 单模时钟恢复模块
Agilent 83494A 单模时钟恢复模块
Agilent 8349 时钟恢复模块
Agilent 83496A 光电时钟恢复模块
Agilent 8