Model(Note: Final DashNo. is Area Ratio) | Approximate Stall Point: | Approximate Practical Pressures Based on 95 PSI Drive,50% Efficiency s/N2 | Maximum Safe Pressure PSI | Actual In Per Cycle | |
| |
Outlet PSI (Max) | Inlet PSI (Min) | Outlet | Inlet | |
Single Acting, Single Drive (Single Stage) | | |
5G-SS-7 | 7 x Drive Air (No assist from gas inlet) | 650 | 50 | 2,500 | 2,500 | 13.20 | | |
5G-SS-14 | 14 x Drive Air (No assist from gas inlet) | 1,300 | 100 | 2,500 | 2,500 | 13.20 | | |
5G-SS-30 | 30 x Drive Air (No assist from gas inlet) | 2,800 | 200 | 9,000 | 9,000 | 3.10 | | |
5G-SS-50 | 50 x Drive Air (No assist from gas inlet) | 4,500 | 300 | 15,000 | 15,000 | 1.76 | | |
5G-SS-75 | 75 x Drive Air (No assist from gas inlet) | 7,000 | 500 | 25,000 | 25,000 | 1.20 | | |
Single Acting, Double Drive (Single Stage) | | |
5G-SD-60 | 60 x Drive Air (No assist from gas inlet) | 5,700 | 400 | 9,000 | 9,000 | 3.10 | | |
5G-SD-100 | 100 x Drive Air (No assist from gas inlet) | 9,000 | 450 | 15,000 | 15,000 | 1.76 | | |
5G-SD-150 | 150 x Drive Air (No assist from gas inlet) | 14,000 | 500 | 25,000 | 25,000 | 1.20 | | |
Double Acting, Single Drive (Single Stage) | | |
5G-DS-4 | (4 x Drive Air) + (1.00 x Gas Inlet) | 400 | 50 | 1,250 | 1,250 | 24.10 | | |
5G-DS-7 | (7 x Drive Air) + (1.00 x Gas Inlet) | 700 | 50 | 2,500 | 2,500 | 26.40 | | |
5G-DS-14 | (14 x Drive Air) + (1.00 x Gas Inlet) | 1,400 | 100 | 4,500 | 4,500 | 14 | | |
5G-DS-30 | (30 x Drive Air) + (1.00 x Gas Inlet) | 3,000 | 200 | 9,000 | 9,000 | 6.20 | | |
5G-DS-50 | (50 x Drive Air) + (1.00 x Gas Inlet) | 5,000 | 300 | 15,000 | 15,000 | 3.52 | | |
5G-DS-75 | (75 x Drive Air) + (1.00 x Gas Inlet) | 7,500 | 500 | 25,000 | 25,000 | 2.40 | | |
Double Acting, Double Drive (Single Stage) | | |
5G-DD-14 | (14 x Drive Air) + (1.00 x Gas Inlet) | 1,400 | 100 | 2,500 | 2,500 | 26.40 | | |
5G-DD-28 | (28 x Drive Air) + (1.00 x Gas Inlet) | 2,800 | 180 | 4,500 | 4,500 | 14 | | |
5G-DD-60 | (60 x Drive Air) + (1.00 x Gas Inlet) | 6,000 | 400 | 9,000 | 9,000 | 6.20 | | |
5G-DD-100 | (100 x Drive Air) + (1.00 x Gas Inlet) | 10,000 | 450 | 15,000 | 15,000 | 3.52 | | |
5G-DD-150 | (150 x Drive Air) + (1.00 x Gas Inlet) | 14,500 | 500 | 25,000 | 25,000 | 2.40 | | |
Two Stage, Single Drive | | |
5G-TS-4 | (4 x Drive Air) + (1.00 x Gas Inlet) | 380 | 10 | 1,250 | 1,250 | 12 | | |
5G-TS-7/14 | (14 x Drive Air) + (2.00 x Gas Inlet) (b,c) | 1,350 | 30 | 4,500 | 2,500 | 13.20 | | |
5G-TS-7/30 | (30 x Drive Air) + (4.29 x Gas Inlet) (b,c) | 3,000 | 60 | 9,000 | 2,500 | 13.20 | | |
5G-TS-14/30 | (30 x Drive Air) + (2.14 x Gas Inlet) (b,c) | 2,900 | 60 | 9,000 | 4,500 | 7 | | |
5G-TS-14/50 | (50 x Drive Air) + (3.57 x Gas Inlet) | 4,500 | 100 | 15,000 | 2,500 | 7 | | |
5G-TS-30/50 | (50 x Drive Air) + (1.66 x Gas Inlet) (b,c) | 5,000 | 500 | 15,000 | 9,000 | 3.10 | | |
5G-TS-14/75 | (75 x Drive Air) + (5.36 x Gas Inlet) (b,c) | 7,700 | 150 | 25,000 | 4,500 | 7 | | |
5G-TS-30/75 | (75 x Drive Air) + (2.50 x Gas Inlet) (b,c) | 7,500 | 130 | 25,000 | 9,000 | 3.10 | | |
5G-TS-30/92 | (92 x Drive Air) + (3.06 x Gas Inlet) (b,c) | 9,000 | 150 | 25,000 | 9,000 | 3.10 | | |
5G-TS-50/92 | (92 x Drive Air) + (1.84 x Gas Inlet) (b,c) | 9,000 | 600 | 25,000 | 15,000 | 1.76 | | |
Two Stage, Double Drive | | |
5G-TD-14/28 | (28 x Drive Air) + (2.0 x Gas Inlet) (b,c) | 2,600 | 200 | 4,500 | 2,500 | 13.20 | | |
5G-TD-14/60 | (60 x Drive Air) + (4.28 x Gas Inlet) (b,c) | 6,000 | 200 | 9,000 | 2,500 | 13.20 | | |
5G-TD-28/60 | (60 x Drive Air) + (2.14 x Gas Inlet) (b,c) | 6,000 | 120 | 9,000 | 4,500 | 7 | | |
5G-TD-28/100 | (100 x Drive Air) + (3.57 x Gas Inlet) (b,c) | 10,000 | 500 | 15,000 | 4,500 | 7 | | |
5G-TD-60/100 | (100 x Drive Air) + (1.66 x Gas Inlet) (b,c) | 10,000 | 1,000 | 15,000 | 9,000 | 3.10 | | |
5G-TD-28/150 | (150 x Drive Air) + (5.36 x Gas Inlet) (b,c) | 14,500 | 150 | 25,000 | 4,500 | 7 | | |
5G-TD-60/150 | (150 x Drive Air) + (2.50 x Gas Inlet) (b,c) | 14,000 | 150 | 25,000 | 9,000 | 3.10 | | |