防爆排风扇方型生产厂家 ,BFAG-500防爆排风扇,防爆换气扇
BFAG隔爆型防爆排风扇,BFAG-300防爆排风扇(以下简称排风扇)其防爆性能按GB3836.1-8《爆炸性环境用防爆电气设备通用要求》GB3836.2-83《 爆炸性环境用防爆电气设备隔爆型电气设备“d”》的规定制成隔爆型。 防爆标志为dⅡBT,适用于Ⅱ类 , A、B、级T1、T2、T3、T4,温度组,可燃性气体与空气形成的爆炸性环境。本品具有防爆性能可靠、风量大、噪声小、耗电省等优点.
BFAG explosion-proof fan, BFAG-300 explosion-proof fan (hereinafter referred to as the fan)the explosion-proof performance according to GB3836.1-8 "electrical apparatus for explosive atmospheres - General requirements for" GB3836.2-83 "electrical apparatus for explosive atmospheres - flameproof electrical apparatus" d "" provisions made of explosion-proof. Ex mark D II BT, suitable for class II, A, B, T1, T2, T3, T4, temperature, environment of explosiveflammable gas and air to form. This product has the advantages of reliable explosion-proof performance, large volume, low noise, low power consumption and so on.
防爆排风扇方型生产厂家 ,BFAG-500防爆排风扇,防爆换气扇 Application 1.适用于1区、2区危险场所; 2.适用于ⅡA、ⅡB类,温度组别为T1~T4的爆炸性气体环境。 1.Can be used in zone 1, zone 2 dangerous places. 2.Suitable for A, II, II class B, temperature classes for T1~T4 explosive gas environment. |
Features 1.防爆排风扇由防爆电机、叶片、面板等部分构成; 2.防爆排风扇面板选用优异钢板焊接成型,叶片由铝合金压铸成型,外表高压静电喷塑; 3.外形漂亮、选用一体式设备,安全可靠,且带有减振设备,运行噪音低; 4.钢管布线。 1.Explosion proof fan made of explosion-proof motor, blades, panels and other parts; 2.The explosion-proof exhaust fan is formed by welding of quality steel plate, the blade is made of aluminum alloy die-casting molding, with high-pressure electrostatic plastic sprayed surface; 3.Aesthetic appearance, integrate ong-body assemble frame, safe and secure, with damping device and low-operacting noise. 4.Conduit wiring . |
产品型号 | 风叶直径mm | 风量m3/h | 额定电压V | 电机功率W | 转速rpm | 安装孔尺寸mm |
BFAG-300 | 300 | 2200 | 220/380 | 120 | 1450 | 300×300 |
BFAG-400 | 400 | 2400 | 180 | 1450 | 380×380 |
BFAG-500 | 500 | 4900 | 250 | 1450 | 440×440 |
BFAG-600 | 600 | 9500 | 370 | 1450 | 520×520 |
安装与使用:
1.首要检查构造、风叶有无变形,扇叶滚动是不是灵敏,有无抵触表象。检查全部坚固件是不是彻底、拧紧,应有防爆合格证编号。
2.线路电压有必要与电机上额外电压相符。
3.用500V兆欧表检查电动机的绝缘电阻,其电阻值若小于5MΩ,则运用烘干法或短路电流法进行单调处理,使其绝缘电阻大于5MΩ。
4.有必要配用小型防爆开关作电源开关,润发防爆或将一般开关装置于室外无爆炸性的本地。
5.接电源的电缆外径与密封圈相符,拧紧、压紧螺母后应保证密封圈与电缆间,密封圈与出线咀间无空地,否则将推动隔爆功用。
6.装置时就保证防爆空地小于0.2mm,更换电机轴承的润滑脂,其润滑脂Pai号为ZG-2H复合钙基润。
7.防爆电动机非接线有些不行随意白拆开,接线时,翻开接线室的盖,穿入引线接到端子上,接了后,盖上盖拧紧螺钉使其隔爆面空地小于0.2mm,再上紧出线器,使引线不能窜动。留心:装置时,留心隔爆面。装置时隔爆面须涂204-1防锈油脂。全部防爆面不得有危害或锈蚀,否则将失掉防爆功用,如有危害或锈蚀表象需按《防爆电气设备防爆面缺陷处理的规则》进行补修。
8.运用中的排风扇应常常清扫电机上粉尘及其它堆集物,防止影响散热。
9.长时间不用的排风扇从头运用时,应按说明书再检查一遍,适合后方可运用。