DC OUTPUT |
| Output Volts (V) | Output Amps (A) |
GPR-60H15D | 0 ~ 600 | 0 ~ 1.5 |
CONSTANT VOLTAGE OPERATION |
Regulation | Line regulation ≦ 0.01% + 3mV Load regulation ≦ 0.01% + 5mV (<10A) Load regulation ≦ 0.02% + 5mV (≧10A) |
Ripple & Noise | ≦ 2mVrms (5Hz ~ 1MHz) |
Recovery Time | ≦ 100μS ( 50% Load change, Minimum load 0. ) |
Output range | 0 to rating voltage continuously adjustable |
CONSTANT CURRENT OPERATION |
Regulation | Line regulation ≦ 0.2% + 3mA Load regulation ≦ 0.2% + 3mA |
Ripple Current | ≦ 5mArms (≦ 20A) ≦ 20mArms (≦ 50A) ≦ 100mArms (≦ 100A) |
Output Range | 0 to rating current continuously adjustable |
METER |
Type | 3 1/2 Digits 0.5" LED Display |
Accuracy | ± ( 0.5% of rdg + 2 digits ) |
INSULATION |
Chassis and Terminal | 100MΩ or above (DC 1000V) |
Chassis and AC Cord | 100MΩ or above (DC 1000V) |
POWER SOURCE | |
| AC120V±10%, 50/60Hz ( AC 220V or 240V order made) |
ACCESSORIES |
| User manual x 1 Test lead GTL-105 x 1 (≦3A), or GTL-104 x 1 (≦10A), or Not available (>10A or 600V) |
DIMENSIONS & WEIGHT | |
| 430(W) x 178(H) x 572(D)mm Approx. 29.5kg |