Promag measuring devices offer you cost-effective flow measurement with a high degree of accuracy for a wide range of process conditions.
电磁流量计Promag 55H系列德国E+H
The uniform Proline transmitter concept comprises:
-
Modular device and operating concept resulting in a higher degree of efficiency
-
Software options for: electrode cleaning, advanced diagnostics, calculation of mass flow and solids content
-
Uniform operating concept
-
The tried-and-tested Promag sensors offer:
-
Excellent accuracy and repeatability
-
Optimum operational safety due to advanced, permanent self-diagnosis
-
No pressure loss
-
Not sensitive to vibrations
-
Simple installation and commissioning
Electromagnetic flowmeter for bidirectional measurement of liquids with a minimum conductivity of ≥ 5 μS/cm - in particular fluids with solids, inhomogeneous or tend to build-up, for example:
-
Fruit mashes, fruit concentrates and final products (salad dressings, soups with vegetable pieces)
-
Beverages, e.g. fruit juice, beer, wine
-
Dairy products, fruit juice mixes
-
Saline solutions
-
Acid, alkalis, etc.
-
Chemically inhomogeneous fluids (e.g. additives)
-
Flow measurement up to 4700 dm3/min (1250 gal/min)
-
Fluid temperature up to +150 °C (+302 °F)
-
Process pressures up to 40 bar (580 psi)
-
Fitting lengths as per DVGW/ISO
-
CIP/SIP cleaning
-
Stainless steel housing
Approvals in food sector/hygiene sector:
Application-specific lining material:
Approvals for hazardous area:
Connection to process control system:
-
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus
-
-
测量原理 | Electromagnetic |
Product headline | Volume flow meter for measurement of demanding conductive fluids in hygienic / food / process applications |
Sensor features | S-DAT, T-DAT, F-CHIP Quick Set-Up ECC 3 totalizers Bi-directional totalizer Pulsating flow Density function Massflow (using density input) Diagnostics 3A authorization and EHEDG-tested |
Nominal diameter range | DN 2...150 1/12"...6" |
Max. measured error | ±0.25% |
Measuring range | 0...600 m3/h |
Max. process pressure | PN16...40 |
Medium temperature range | -20...+150°C (-4...+302°F) |
Degree of protection | IP 67 (NEMA 4x) |
Display/Operation | Four line display with backlit Touch control |
Outputs | 4...20 mA Pulse / frequency(active/passive) Relais Status |
Inputs | Status Current input |
Digital communication | HART PROFIBUS PA FOUNDATION Fieldbus |
Hazardous area approvals | ATEX FM CSA |