Pocket Multimeter_5133333_Normal ModulePen multimeter DM73B
Pen multimeter for one-handed operation
Ideal for measurement work in cramped spaces
3400 digit visual display
Automatic range selection
Display lock (data hold function)
Continuity test with beeper
Automatic power off
Safety: CAT II 600 V or CAT III 300 V
Technical specifications |
DC voltage | |
Ranges: | 420 mV, 4.2 V, 42 V, 300 V |
Accuracy mV, 4.2 V, 42 V: | ± 0.5 % vMW ± 4 Dgt |
300 V | ± 0.7 % vMW ± 1 Dgt |
Input impedance (4.2 V range): | 11 MΩ |
AC voltage | |
Ranges: | 4.2 V, 42 V, 300 V |
Accuracy 50 Hz–500 Hz: | ± 1.5% vMW ± 8 Dgt |
Input impedance (4.2 V range): | 11 MΩ |
Resistance | |
Ranges: | 420 Ω, 4.2 kΩ, 42 kΩ |
| 420 kΩ, 4.2 MΩ |
Accuracy 420: | ± 1.5% vMW ± 6 Dgt |
4.2K–420k: | ± 0.7% vMW ± 4 Dgt |
4.2 m: | ± 1.2% vMW ± 4 Dgt |
Continuity test: | Audible and visual display |
Threshold: | <50 Ω |
Display lock: | Yes |
Overload protection: | |
DCV/ACV: | 300 Vac/dc, peak (1 min) |
Resistance: | 250 Vdc/ac max (1 min) |
Display capacity: | 4199-point LCD |
Battery life: | 100 hour type; autom. power-off |
Mode of functioning: | Double platform integration |
Measuring rate: | 2/S |
Operating temperature: | 0°C → 40°C |
Storage temperature: | -20 °C → 60 °C |
Battery type: | Two LR-44, 1.5 V alkali-magnesium Button cells |
Dimensions (H x W x D): | 165x28x19 mm |
Weight: | 75 g |
标准
CAT II 600 V or CAT III 300 V