MODEL | 631 | 6330A | 6360A | 6390A | 63120A | 63150A | 63180A |
INPUT |
Phase | 3ø |
Voltage | 220/380Vac±10% |
Frequency | 47-63Hz |
Max. Current (approx) | 40A | 7 | 150A | 230A | 300A | | |
Power Factor | | 0.8 |
OUTPUT |
Max. Power | Single-Phase | 5KVA | 10KVA | 20KVA | 30KVA | 40KVA | 50KVA | 60KVA |
Total Power | 15KVA | 30KVA | 60KVA | 90KVA | 120KVA | 150KVA | 180KVA |
Max. Current (r.m.s) , Single-Phase*1 | 0-150V | 42.0A | 84.0A | 168.0A | 252.0A | 336.0A | 420.0A | 504.0A |
0-300V | 21.0A | 42.0A | 84.0A | 126.0A | 168.0A | 210.0A | 252.0A |
Max. Current (r.m.s), Single-Phase (Option 0-600V)*2 | 0-300V | 21.0A | 42.0A | 84.0A | 126.0A | 168.0A | 210.0A | 252.0A |
0-600V | 10. | 21.0A | 42.0A | 63.0A | 84.0A | 105.0A | 63.0A |
Phase | 3ø/4W |
Total Harmonic Distortion (T.H.D) | < 1% at 360~440Hz or 760~840Hz (Option) at Resistive Load |
Crest Factor | ≥3 |
Line Regulation | ± 0.1V |
Load Regulation | L - N : ± (0.5% of output +0.5V) / L - L : ± (1% of output +1V) at Resistive Load |
Deviation of phase angle | 120° ≤ ±1° at Load Balance, 120° ≤ ±2.5° at Load Unblance |
Response Time | < 2 msec |
SETTINGS |
Voltage | Range | 0-150V/0-300V Selectable or 0-300V/0-600V Selectable(Option 0-600V) |
Resolution | 0.1V |
Accuracy | ±(1% of setting + 2counts) |
Frequency | Range | 360-440Hz or 760~840(Option) Full Range Adjust |
Resolution | 0.1Hz |
Accuracy | ±0.02% of setting |
MEASUREMENT |
Voltage | L - N Range | 0.0-300.0V / 0.0-600.0V(Option 0-600V) |
L - L Range | 0.0-520.0V / 0.0-1040V(Option 0-600V) |
Resolution | 0.1V / 0.2V |
Accuracy | ± (1% of reading + 2counts) |
Frequency | Range | 360.0-440.0Hz; 760.0~840.0Hz (Option) |
Resolution | 0.1Hz |
Accuracy | ±0.1Hz |
Current (r.m.s) | Range | L | 0.00-35.00A | 0.0-350.0A |
H | 30.0-350.0A | 300-504A |
Resolution | L | 0.01A | 0.1A |
H | 0.1A | 1A |
Accuracy | L | ± (1% of reading +2counts) |
H | ± (1% of reading +1count) |
Current (r.m.s) (Option 0-600V) | Range | L | 0.00-35.00A |
H | 30.0-350.0A |
Resolution | L | 0.01A |
H | 0.1A |
Accuracy | L | ± (1% of reading +2counts) |
H | ± (1% of reading +1count) |
Power | Range | L | 0.000-3.500W | 0.00-35.00KW |
H | 3.00-40.00W | 30.0-60.0KW |
Resolution | L | 0.001W | 0.01KW |
H | 0.01W | 0.1KW |
Accuracy | L | ± (1.5% of reading +5counts) |
H | ± (1.5% of reading +1count) |
Power Factor | Range | 0.000-1.000 |
Resolution | 0.001 |
Accuracy | W / V x A , Calculated and displayed to three significant digits |
GENERAL |
PLC Remote | I/P:ON/OFF, P1, P2, P3, O/P:Processing |
Memory | 8 Memoies, 5steps per memory for Voltage, Frequency, Test Time, Delay time and Current, Power, Power Factor Hi, Lo Limit setting. |
Timer | 0=Continuous, 1-9999 (Unit: sec, minute, hour selectable) |
Auto Loop Cycle | 0=Continuous, OFF=Loop Once, 2~9999 (Unit:×1, ×10, ×100) |
Auto Voltage Adjust | Enable it for improve voltage regulation within ±0.1V |
Efficiency | ≧85%(at Full Load ) |
Protection | Over Load , Short Circuit , Over Temperature |
Calibration | Front Panel Calibration |
Interface (Option) | GPIB/RS232 |
Operation Environment | 0-40℃/20-80%RH |
Dimension, mm | W | 430 | 600 | 800 | 1200 | 1200 | 1600 | 1600 |
H | 732 | 842 | 1242 | 1557 | 1557 | 1800 | 1800 |
D | 650 | 900 | 900 | 900 | 900 | 1100 | 1100 |
Net Weight | 207Kg | 366Kg | 487Kg | 820Kg | 1300Kg | 1800Kg | 2100Kg |
*1 At working voltage 120/240V | product specifications are subject to change without notice. |
*2 At working voltage 240V/480V | |