Standard Versions
Information on general and metrological features (e.g tem-
perature resistance) and temperature ranges / error limits /
smallest subdivision can be found in model overview 8000.
Measuring Unit
With nitrogen fi lling
(inert gas, physiological harmless)
Accuracy (EN 13 190)
Class 1
Case
With polished crimped-on ring, 1.4301 (304 stainless steel)
Case Protection Type (EN 60 529 / IEC 529)
IP 65
Case Filling
For model TFChgG: silicone oil
Nominal Case Sizes
63, 80, 100, 160 (mm) (2½", 3", 4", 6")
Case Confi guration
Connection temperature
sensor (stem): capillary line
Capillary line position: vertical bottom position,
optional: centre back position (rm),
see page 2
Mounting device:
for bottom capillary line position:
back fl ange for surface mounting (Rh)or
mounting device for
gauge holder bracket (Mgh)
for centre back capillary
line position (rm): back fl ange for surface mounting (Rh) /
front fl ange (Fr),
or u-clamp for panel mounting (BFr)
Capillary Line(standard)1m stainless steel Ø 2mm, with buckle
protection spirals at both ends
capillary line length L
FL
selectable from
1m up to 15 m (> 15 m upon request)
Temperature Ranges (EN 13 190)
Temperature differences from 80 K to 600 K
Temperature Sensor (Stem)
1.4571 (316 stainless steel),
max. static operating pressure: 25 bar
Stem models: A1, A3, A4, A5 or A6,
Stem- Ø dF: 8, 10 or 12 mm
Stem length L resp. L1: Lmin resp. L1min up to max. 2.50 m
Please regard the minimum stem length against the active length
(La) and stem model, see page 3.
Ordering Information, Standard Temperature Ranges, Option
See page 4
Special Versions and further Options among others
• Other stem models, e. g.
- without bent tube, with compression fi tting,
adjustable at capillary line see data sheet 8299.2
- with connection for food- / biotechnics / pharmaceutical indust
see data sheet 8299.3
- contact stem for temperature measurement at the outsides
of the cases and pipe barrels up to 300 °C,
see data sheet 8299.4
• Other stem-Ø, connection thread and materials upon reques
• Capillary line F
FL
> 15 m upon request
• Other temperature ranges and/or special scales, e.g.
double scale °C/°F, coloured fi elds or areas,
dial inscriptions, etc.
• Case parts 1.4404 (316 stainless steel) upon request
• Model TFChg for ambient temperatures up to -60°C;
Model TFChgG for ambient temperatures up to -40 °C,
up to -60°C NCS 100 and 160
• Position of the connection at 3 o´clock, 9 o´clock, 12 o´clock,
others upon request or other than vertical installation (90°)
• GOST-version for Russia, Ukraine, Kazakhstan
Dial
Aluminum, black fi gures, white background
Pointer
Aluminum, black
Zero Adjustment(± 6%)
Externally by a screw