| APS-1102 | | |
Z大输出容量 | | | |
AC | 输入(100~180V) | 750VA | |
| 输入(180~250V) | 1000VA | |
DC | 输入(100~180V) | 750W | |
| 输入(180~250V) | 1000W | |
输出电压 | | | |
AC | 100V | 0.0V~135.0V | |
| 200V | 0.0V~270.0V | |
DC | 100V | -190.0V~+190.0V | |
| 200V | -380.0V~+380.0V | |
Z大输出电流 | | | |
AC | 100V | 10A | |
| 200V | | |
DC | 100V | 10A | |
| 200V | | |
Z大输出峰值电流 | | | |
| 100V | 40Apk | |
| 200V | 20Apk | |
频率 | | | |
| 设置范围 | 1.0Hz~550.0Hz | |
| 设置精确度 | ±100ppm | |
波形 | | | |
| 正弦波,方波, 任意波 (16 种) | | |
| 输出电压失真率 | 0.5% MAX(50HZ/60HZ) | |
线性电压规格 | | | |
| 输入电压 | 100V/120V/230V, 无负载,额定输出 | |
负载电压调整率 | | | |
| | 0.5% MAXIMIM (在输出端空载与额定的电阻负载内) | |
测量 | | | |
| 范围 | 分辨率 | 精确度 |
计频器 | 1.0 ~550.0 Hz | 0.1Hz | ±100ppm(1.0 Hz to 550.0Hz) |
有效值电压表(AC+DC) | Full Scale 100V:225.0Vrms | 0.1Vrms | ±0.5% of the full scale |
| Full Scale 200V:450.0Vrms | 0.1Vrms | ±0.5% of the full scale |
有效值安培表(AC+DC) | Full Scale 15.00A | 0.01Arms | ±1.0% of the full scale |
功率计 | Full Scale 1200W | 1W | ±2% of the full scale |
负载功率因数测量 | 0.00 ~ 1.00 | 0.01 | |
负载振幅因数测量 | 0.00 ~ 50.00 | 0.01 | |
外部同步 频率测量 | 38.0~525.0Hz | 0.1HZ | ±0.2Hz |
输出打开时的相位 | 0.0°~359.9° | 0.1° | |
外部信号输入 | | | |
增益输出设定 | 100V range 0.0~200.0 times | 0.1 | ±5% |
| 200V range 0.0~400.0 times | 0.1 | ±5% |
| | | |
输出模式 | | | |
| | | |
ACINT | | | |
AC-EXT | | | |
AC-ADD | | | |
AC-SYNC | | | |
AC+DC-INT | | | |
AC+DC-EXT | | | |
AC+DC-ADD | | | |
AC+DC-SYNC | | | |
| | | |
内存 | | | |
存储/调取 | 30 组 | | |
电源 | | | |
| AC100V~230V±10% 50Hz / 60Hz ±2Hz | | |
功率损耗/因数 | | | |
| 1.4kVA max / 0.95min(AC100V) 0.9min(AC200V) | | |
接口 | | | |
| USB(USBTMC) 标准 | | |
尺寸& 重量 | | | |
| 258mm(W) X 176mm(H) X 440mm(D) 大约:9.5 kg | | |