GSC2-NF系列机械联锁交流接触器
GSC2-NF Range Machine Interlock AC Contactor
一、用途 APPLICATION
GSC2-NF系列机械联锁交流接触器适用于交流50Hz(或60Hz),额定工作电压至660V,在AC3使用类别下额定工作电压为380V时,额定工作电流115-630A(在额定工作电压为380V时)的电路中,控制可逆运转或可反向制动的电 动机以及双电源控制,并和适当的热过载继电器组合,以保护可能发生过负荷 的电路。
GSC2-NF range machinery interlock AC contactor is used in AC 50Hz (or
60Hz), rated working voltage is up to 660V, and rated current 115-630A under rated voltage 380V and AC-3, for reversible control or reverse control operation motor and double-power control, may with the appropriate thermal overload relay arrangement, to protect potential overload circuit.
二、技术参数
AC-3 使用类别下额定工作电流(le)A :380V—11, 660V--86A
AC-4 使用类别下额定工作电流(le)A :380V—52A, 660V--49A
AC-3 可控制三相 鼠笼型电动 机额定功率: 380V—55KW, 660V--80KW
AC-4 可控制三相 鼠笼型电动 机额定功率: 380V—25KW, 660V--45KW
主触头为四常开不带辅助触头
约定发热电流 lth A :200
额定工作电压 Ue V: 380 ; 660
额定绝缘电压 Ui V:100
AC-3(6le,le)电寿命(次): 60×100000
AC-3(6le,le)操作频率 h-1:600
AC-3(6le,6le)电寿命(次): 1500000
AC-3(6le,6le)操作频率 h-1:150
AC-3(6le,6le)额定工作电流: 380V--28A 660V--14A
线圈参数--额定控制电压(Us)V: AC:24、 48、110、220、380
线圈参数--吸合时间: 0.85 Us~1.1 Us
线圈参数--AC释放时间: 0.2 Us~0.75 Us
线圈参数--DC释放时间: 0.1 Us~0.75 Us
线圈参数--AC线圈吸合功率VA:550
线圈参数--AC线圈保持功率VA:45
线圈参数--DC线圈吸合功率VA:550
线圈参数--DC线圈保持功率VA:4
线圈参数--吸合时间ms:23-35
三、工作条件和安装条件
WORKING CONDITION AND INSTALLATION WAY
△ 周围空气温度-5℃~+40℃,24小时的平均值不超过+35℃。
Ambient temperature: -5℃~+40℃. Average temperature ≤+3 5℃ in 24H;
△ 海拔高度:不超过2000m。 Elevation ≤2000m
△ 大气条件:安装地点的空气相对湿度在Z高温度为+40℃时不超过50%,在较低 温度下可以有较高的相对湿度;Z湿月的月平均Z低温度不超过+25℃,该月的 月平均Z大相对湿度不超过90%;并考虑因温度变化发生产品上的凝露;
Air condition: Relative humidity is not exceeding 50% at the maximum ambient temperature +40℃ . With lower temperature, higher humidity would be permitted. And average maximum relative humidity ≤90% in the most humidity month, at the same time, the average minimum temperature should ≤+25℃, and should give consideration to dews on the good surface, which would appear due to temperature change.
△ 产品应安装和使用在无显著摇动、冲击和振动的地方。
Contactor should be installed at no significant sharking or vibration place.
△ 安装方式:螺钉安装; Installation way: by screw
△ 安装类别为:“安装类别III”; Installation categories: class III
△ 污染等级为:“污染等级3”;Pollution grade: Grade 3
△ 安装角度:垂直安装,安装面与垂直面的倾斜度不大于±5°。
Installation gradient: vertical installed, the tilt gradient with vertical face should ≤±5°
四、使用注意事项 NOTICE
在使用过程中,机械联锁交流接触器的银触点,经过一定次数的接通和分断 操作后,银触点表面呈现烧毛或发黑现象,这不影响使用,不要锉平磨光,否则会降低触点使用寿命,若烧毛比较严重,影响接触时,可用油光锉轻轻锉光,
在银触头磨损到露出铜接触板之前仍可正常使用。
In operate procession, contactor's silver contact will appear black phenomenon after a certain number of making and breaking, which does not affect work, don't need file-polished, otherwise will reduce silver contact life. If appear serious black and impact contact, can be glossed shiny by nail, the silver contact can be normally used before exposing silver plate
五、订货须知 ORDER REMARK
■ 订货时应注明下列事项 In order need attention following
△ 机械联锁交流接触器的全型号及名称; Entitle type and name of contactor;
△ 控制线圈的频率及电压; Frequency and voltage of control coil;
△ 订购数量: Order volume
△ 例如:GSC2-265NF机械联锁交流接触器,交流50Hz/60Hz 220V 10台。 Example: GSC2-265NF machinery interlock AC contactor, AC 50Hz/60Hz
220V 10 sets.
△ 产品的线圈为易损部件,可以单独订货,按照表4写明线圈电压规格代号及数 量。
The coil is vulnerable component, can separate order, table 4 states coil voltage specifications code and the number.
△ 例如:LX1-FF048 10件 Example: LX1-FF048 10sets
△ 线圈电压未列入表4中的规格,如用户需要可特殊订货。
If user need the coil not contained in table 4, please specially customize