日本横河YOKOGAWA
CA11E电压电流校正器日本横河YOKOGAWA
CA11E毫安豪伏信号发生器CA11E电压电流校正器具有电压电流的输出及量测功能
4~20mA及1~5V DC分段输出之升/降功能
20mA电流吸收功能,以仿真两线式转换器
清除功能,可程序化变更输出条件,以DIP开关调整
CA11E电压电流校正器规格:
(输出)
直流电压: 30V/10V/1 to 5V/1V/100mV
直流电流: 20mA/4 to 20mA/20 mA SINK
(量测)
直流电压: 30V/10V/1V/100mV
直流电流: 20mA
CA11E电压电流校正器一般规格:
·外部尺寸:大约 90 (W) x 192 (H) x 42 (D) mm
·重量:约 440g(含电池)
·电源: 4个AA尺寸碱性干电池或订购特殊的交流变压器
- Source and Measuring of Voltage and Current:
General and measures voltages up to 30V DC and current up to 24 mA DC - Improved display resolution for current
The generation /measurement resolution has inproved to 0.001mA - 24VDC(20mA) Loop check function
- 4-20 mA and 1-5 VDC Step-up/down Function:
The output level can be changed between 1?2?3?4?5V signals for the 1 to 5V DC output, for efficient calibration work. - 20 mA SINK Function:
Absorb the voltage supplied from an external power supply to its H terminal and simulates a two-wire transmitter, idea for loop checks. - Sweep Function:
Increase and decrease the output level to the preset level at a constant rate for the selected sweep time (16 or 32 seconds). The sweep function and sweep time are set by the internal dip switch.