执行标准:IEC 61730-2:2004、IEC 61032:1997
该探头可用于检测对人的手指误接触危险部件保护,也用来检测接线盒开口机械强度:
材料:金属,除另有指定
尺寸允许误差,在没有特别指定情况下遵循:对角度:0~ -10°
ZX线尺寸:
25mm以内:0~ -0.05mm
25mm以上:± 0.2 mm
连接处之间应允许在同一平面和同一方向是*穿过90°角度(0~10°误差)活动。这探针特意用来检测对误接触危险部分的基本保护,其试验指也被用来检测安全保护。
试验指应用的施压:10,20,50,75N
BR-PV-AF Accessibility Test Finger
Implementation of standards: IEC 61032-1997, IEC 61730:2-2004 & Ed.2, UL 1703-2008, VDE 0126-5:2008, VDE 0126-3:2009, IEC 60529:2001...
This probe may be used to verify the protection of persons against access to hazardous parts, and to verify the mechanical strength of openings in the enclosure or internal barriers.
Fibger Technical index:
Tolerance on dimensions when no specific tolerance is given: on angles 0~ -10°
On linear dimensions:
up to 25 mm: 0~ -0.05mm
over 25 mm: ± 0.2mm
Test probe B: Both joints shall permit movement in the same plane and the same direction through an angle of 90° with a 0° to +10° Tolerance.
Test probe 11: Different force requirement, 50N for IEC 61730 Ed.1 (quote IEC 61032:1997), 10N±10% for IEC 61730 Ed.2.
Attachment: Ohm meter for IEC 61730
Standard | Test force | Test subject | Finger type |
IEC 61032:1997 | 50N | Module | Test probe 11 |
IEC 61730 Ed.2 | 10N±10% | Module | Test probe 11 |
UL 1703-2008 | The minimum force necessary toaccuray determine accessibility | Module | Test probe B |
VDE 0126-5:2008 | 75N | Junction box | Test probe 11 + probe B |
VDE 0126-3:2009 | 20N | Connector | Test probe 11 |
Application in VDE 0126-5 and VDE 0126-3, junction box and connector test conditions are as follows:
1. Fixing of lid at rewireable junction box - Screwless fixing of lid: Enclosures shall be tested with the test probe 11 according to IEC 61032 applied with a force of 75N for one minute to all points where this could cause a loosening of the lid. During test the lid shall not come off.
2. Protection against electric shock: Connectors shall be tested by t he IEC test finger in accordance to IEC 60529 using a test force of 20N.