HI255型酸度/电导率/总固体溶解度/盐度测定仪 |
酸度测量范围 | pH:-2.00-16.00pH-2.000-16.000pH;ORP:±699.9mv;±2000mv |
酸度解析度 | pH:0.01pH,0.001pH;ORP:0.1mv(±699.9mv),1mv(±2000mv) |
酸度精度 | pH:±0.01pH,±0.002pH;ORP:±0.2mv(±699.9mv),±1mv(±2000mv) |
电导率测量范围 | 0.00-29.99µS/cm,30.0-299.9µS/cm,300-2999µS/cm,3.00-29.99mS/cm,30.0-200.0mS/cm,up-500mS/cm(不使用温度补偿功能时实际的电导值) |
电导率解析度 | 0.01µS/cm,0.1µS/cm,1uS/cm,0.01mS/cm,0.1mS/cm |
电导率精度 | 读数的±0.01%±0.05µS/cm |
TDS测量范围 | 0.00-14.99ppm(mg/L),15.0-149.9ppm(mg/L),150-1499ppm(mg/L),1.50-14.99ppt(g/L),15.0-100.0ppt(g/L),up-400.0ppt(g/L)(不使用温度补偿功能时实际的TDS值) |
TDS解析度 | 0.01ppm,0.1ppm,1ppm,0.01ppt,0.1ppt |
TDS精度 | 读数的±1% ±0.03ppm |
盐度测量范围 | 0.0-400.0%NaCl |
盐度解析度 | 0.1%NaCl |
盐度精度 | 读数的±1% |
温度测量范围 | 酸度温度范围:-10-120.0℃电导温度范围:0.0-6.0℃ |
温度解析度 | 0.1℃ |
温度精度 | ±0.4℃ |
校正方式 | pH/ORP:从pH4.01,pH6.86,pH7.01,pH9.86,pH10.01五个校正点中自动选择1,2和3点校正EC/TDS:从84.0,1413µS/cm,5.00,12.88,80.0,111.8mS/cm六个校正点中自动选择1点校正盐度:单点自动校正(推荐使用HANNA校正缓冲液HI7037L) |
温度补偿 | pH/ORP:自动或手动温度补偿-10.0-120.0℃;EC/TDS:0-60.0℃范围内,温度补偿系数:0.00-6.00%/℃;出厂时设定温度补偿系数为:1.90%/℃ |
TDS转换因子 | 0.40-0.80范围内手动调整(出厂时设定系数为:0.50) |
配套电极 | 电极可依据客户需要选择HI1131或HI1200或其他测量用途的复合电极HI76310高性能的具有测量范围广泛的新型四环电导电极 |
数据接口 | RS-232数据接口(可选购HI92000软件和HI920010数据线) |
数据存储 | 200组 |
输入阻抗 | 1012Ohm |
配套电源 | HI710006专用电源12V DC变压器 |
操作环境 | 0-50℃;RH95% |
尺寸/重量 | 240×182×74mm/1.1Kg |