Input pressure range
Nominal pressure gauge [bar] 6 10 16 25 40 60 100 160 250
Overpressure (static) [bar] 14 35 35 70 140 140 350 350 700
Burst pressure ≥[bar] 28 70 70 140 280 280 700 700 1 400
Vacuum resistance unlimited
Output signal / Supply
Standard 2-wire: 4 ... 20 mA / VS= 8 ... 32 VDC
Options 3-wire: 0 ... 10 V / VS= 14 ... 30 VDC
3-wire ratiometric: VSig= 0.5 … 4.5 V / VS= 5 ± 0.5 VDC
Performance
Accuracy
1
≤ ±0.5 % FSO
Permissible load 2-wire: Rmax= [(VS– VS
min) / 0.02] Ω
3-wire: Rmin= 10 kΩ
Influence effects supply: 0.05 % FSO / 10 V
load: 0.05 % FSO / kΩ
Response time 2-wire: ≤ 10 msec 3-wire: ≤ 3 msec
Measuring rate 1 kHz
1
accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)
Thermal effects (Offset and Span) / Permissible temperatures
Thermal error ≤± 0.3 % FSO / 10 K in compensated range 0 ... 70 °C
Permissible temperatures medium: -40 ... 125 °C electronics / environment:-40 ... 85 °C stora
Electrical protection
Short-circuit protection permanent 3-wire ratiometric: none
Reverse polarity protection no damage, but also no function
Electromagnetic protection emission and immunity according to EN 61326
Mechanical stability
Vibration 20 g, 25 Hz … 2 kHz according to DIN EN 60068-2-6
Shock 500 g / 1 msec according to DIN EN 60068-2-27