Voltage (V) | Ranges (Auto or Manual)(6 range) | 15V 30V 60V 150V 300V 600V RMS |
Display Resolution | 4-1/2 digits |
Scaling Factors | 0.1 to 1000.0 |
Operating Principle | True Rms or mean Value rectification |
Crest Factor | Up to 3 |
Frequency Range | DC and 10Hz to 100kHz(300KHz Only CP-620-2) |
Accuracy(23℃±5℃) | 47 to 63Hz | ±0.05% reading ±0.05% range ±10mV |
DC and 10Hz to 100k Hz | ±0.2% reading ±0.1% range ±0.1% / kHz |
| 50KHz to 300KHz ( Only CP-620-2 ) (建议外加高频电流感测器) | ±0.3% reading ±0.2% range ±0.05% /kHz |
Maximum Input | Continuous | 600V Rms / 1800Vpk |
Effect of Common Mode Voltage | 600V Rms at 60Hz | Less than ± 0.05% of range |
|
Input impedance | 1Mohm and 10pF on all ranges |
Current (A) | Ranges (Auto or Manual) (7 ranges 1-2-5 sequences) | CP-600-2 CP-620-2 CP-660-2 | 0.2A 0. 1A 2A 10A 20A |
CP-600-5 CP-660-5 | 0. 1A 2A 10A 20A 50A |
EXT IN (7 Range) (RMS) | 20mV 50mV 100mV 200mV 500mV 1V 2V |
Display Resolution | 4-1/2 digits |
Scaling Factor | 0.01 to 1000.0 |
Operating Principle | True Rms |
Frequency Range | DC and 10Hz to 100kHz(300KHz Only CP-620-2) |
Crest Factor | Up to 3 |
Accuracy(23℃±5℃) | 47 to 63Hz | ±0.05% reading ± 0.05%range ± 0.1mA |
DC and 10Hz to 100kHz | ±0.2% reading ± 0.1% range ± 0.1%/kHz |
| 50KHz to 300KHz ( Only CP-620-2 ) (建议外加高频电流感测器) | ±0.3% reading ± 0.2% range ± 0.1% /kHz |
Maximum Input | Continuous | 20A/50A Rms.60Apk / 150Apk |
Effects of Common Mode Voltage | 600V Rms at 60Hz | Less than ± 0.05% of range |
- |
Input impedance | CP-600-2 CP-660-2 | 10mohm on all ranges(CP-620 not) |
CP-600-5 CP-660-5 | 3.5mohm on all ranges |
Power (W) | Ranges (Auto or Manual) (42 ranges corresponding to V and A) | 3W to 30kW (with scaling to 99.999MW) |
Display Resolution | 4-1/2 digits |
Operating principle | Analog multiplier Circuit |
Frequency Range | DC and 10Hz to 100kHz(300KHz Only CP-620) |
Crest Factor | Up to 3 |
Accuracy (23℃±5℃) | 47Hz to 63Hz | ±0.1% reading ± 0.1% range ± 5mW |
DC and 10Hz to 50kHz | ±0.2% reading ± 0.1% range ± 0.1%/kHz |