PGT23.100/PGT23.160 德国威卡wika压力
智能型波登管压力表带电信号输出,不锈钢系列,安全型,表圆直径 100,160
型号:PGT23.100/PGT23.160
应 用
Acquisition and display of process values
Transmission of process value to the control room, 4 ... 20 mA; 0 ... 20 mA; 0 ... 10 V
Easy-to-read, local analogue display needs no power supply
Safety-related applications
特别功能
„Plug and play“ means no configuration necessary
Signal transmission in accordance with Namur
Measuring ranges from 0.6 bar to 1000 bar
Easy-to-read, Ø 100 mm analogue display
S3 Safety pressure gauge per EN 837-1
inliGAUGE Model PGT23.100
详 细
Nominal size
100 mm
Accuracy class
Class 1.0
Display range
0 … 0.6 up to 0 … 1000 bar
including all corresponding ranges for negative and/or negative and positive/compound pressure
Wherever the process pressure has to be indicated locally,and, at the same time, signal transmission to a central controller or remote control room is wanted, the PGT23.100 inliGAUGE can be used.
Through the combination of a mechanical measuring system and electronic signal processing, the process pressure can be read securely, even if the power supply is lost. The PGT23.100 inliGAUGE fulfils all safety-related requirements of the relevant standards and regulations for the on-site display of the operating pressure of pressure vessels. An additional measuring point for the mechanical pressure indication can thus be saved.
The PGT23.100 is built upon a high-quality, stainless steel pressure gauge with a 100 mm nominal size. The pressure gauge is manufactured in accordance with EN 837-1.
The durable, fully-welded Bourdon tube measuring system produces a pointer rotation proportional to the pressure. An electronic angle encoder, proven in safety-critical automotive applications, determines the position of the pointer shaft – it is a non-contact sensor and therefore compley free from wear and friction. From this, the pressure-proportional, 4 ... 20 mA electrical output signal is produced.
The electronic WIKA transmitter, integrated into the highquality Model 23x.30 mechanical pressure gauge, combines the advantages of electrical signal transmission with the advantages of a local mechanical display.
The measuring span (electrical output signal) is set automatically along with the mechanical display, i.e. the scale over the full display range corresponds to 4 ... 20 mA. The electrical zero point can also be set manually.
________________________________________________________
Accessory: Power supply for top hat rail input
output max. current description 230Vac 24Vdc 70mA A-VA-1 90…
253Vac 24Vdc 500mA KFA6-STR-1.24.500 12…
30Vdc 4.. 20mA Ex signal isolator
Typ SI 815 20…
35Vdc max. 25,4Vdc 0/4.. 20mA Ex- transmitter power supply
KFD2-STC4-Ex1PGT23.100/PGT23.160 德国威卡wika压力