㊣回收Agilent 8711B二手网络分析仪
涂生:
:
深圳市诚星电子仪器有限公司
地址:深圳市龙华镇民治大道
本公司长期高价 回收:Agilent、HP、FLUKE
Anritsu、Advantest、R/S、MARCONI
网络分析仪、综合测试仪、无线电综合测试仪、万用表校准仪、
频谱分析仪、视频分析仪、音频分析仪、噪声系数分析仪、蓝牙测试仪、
视频图象信号源、LCR测试仪(电桥)、高低频信号源、示波器、万用表、
程控电源、电子负载、频率计、功率计、仪器配件,GPIB卡 等等。
欢迎来电咨询!
高价回收 Agilent5071C Agilent5071B Agilent5071A
Agilent5061B Agilent5061A Agilent5062A
Agilent4401B Agilent4402B Agilent4403B
Agilent4404B Agilent4405B Agilent4406B
Agilent4407B Agilent4408B Agilent4411B
Agilent4412B Agilent4416B Agilent4418B
Agilent4421B Agilent4422B Agilent4428B
Agilent4432B Agilent4433B Agilent4438B
高价回收
Fluke校验校准仪:
Fluke 754过程校准仪
FLUKE 5820A示波器校准仪器
Fluke 718内置压力泵校准器
Fluke 719压力校准器
Fluke 743B过程认证校准器
Fluke 724 温度校准器
Fluke 715 校准器
GE Druck DPI705压力校验仪
Fluke DTX 系列电缆测试仪
高价回收 Fluke5520A Fluke5500A FLUKE287 FLUKE123 FLUKE199 FLUKE199B
Fluke744 Fluke5700A FLUKE45 FLUKE DTX1800 FLUKE DTX1200
300 kHz to 1.3 GHz
Agilent 8713B and 8714B,
300 kHz to 3 GHz
RF Economy Network Analyzers
Configuration Guide
nalyzer,300 kHz to 1.3 GHz
* Agilent 8712B vector network analyzer,
300 kHz to 1.3 GHz
* Agilent 8713B scalar network analyzer,
300 kHz to 3 GHz
?Agilent 8714B vector network analyzer,
300 kHz to 3 GHz
Options
* 75 ohms system impedance, Option 1EC
Converts to 75 ohm system impedance and substitutes
75 ohm Type-N connectors. Substitutes
75 ohm test port cable and demonstration filter.
Use with 75 ohm calibration kits and accessories.
* AM delay for 50 ohm systems, Option 1DA
* AM delay for 75 ohm systems, Option 1DB
(Option 1EC must also be ordered with 75 ohm
systems) Adds amplitude modulation group
delay capability to measure group delay in
frequency-translation devices such as tuners
and receivers. Includes two external broadband
detectors and a power splitter. Not recommended
for devices with limiting circuits, saturated
amplifiers or automatic gain control. For nonfrequency
translation devices the vector network
analyzers 8712B or 8714B offer lower noise and
better accuracy when measuring group delay.
* HP Instrument BASIC (IBASIC)
Option 1C2 IBASIC is a subset of BASIC for
creating and executing test programs inside the
network analyzer, including keystroke capture
and one-button macros, without the need for an
external controller. Includes Instrument BASIC
User’s Handbook (part number 08712-90005)
and IBASIC example program disk (part number
08712-10003).
? Option 100 fault location and structural return loss
Full cable characterization in one package. Fault
location includes convenience features unavailable
in TDRs, including multi-bump, cable calibration,
and cable loss measurements. Structural return
loss, which is the return loss resulting from
many small, equally spaced discontinuities, is
easily and accurately measured. A user manual
and instructional video tape are included.
Agilent 8711B and 8712B,
300 kHz to 1.3 GHz
Agilent 8713B and 8714B,
300 kHz to 3 GHz
RF Economy Network Analyzers
Configuration Guide
2
? 60 dB step attenuator, Option 1E1
Extends output power range down to –60 dBm.
* Extra 50 ohm cable and Type-N (f-f) adapter, Option AFN
* Extra 75 ohm cable and Type-N (f-f) adapter, Option AFP
* Option AF4
This option deletes the Type-N cable and substitutes
two N-to-BNC adapters and a BNC cable.
* Keyboard, Option 1CL
Adds mini-DIN interface keyboard (part number
C1405B, Option ABA), cable, and mini-DIN to
DIN adapter (part number C1405-60015) to
enhance IBASIC editing and instrument control
capability. Keyboard overlay (part number
08712-80004) is supplied with every instrument.
* Rack mount kit, Option 1CM
* Performance test software, Option 1FP
Special Options
Special options are available for unique applications.
Examples include multiport and reversing
test sets. Contact your Agilent representative for
more information.
Documentation
* Deletes manual set, Option 0B0
* Deletes service guide, Option AVB
* Deletes programming guide, Option AV7
* Adds Agilent 8711B, 8713B manual set, Option 0B1;
Also available as part number 08713-90001.
* Adds Agilent 8712B, 8714B manual set, Option 0B1;
Also available as part number 08712-90001.
Localization Options
These options provide a localized user’s guide at
no extra charge. They include information on
installation, instrument functions, optimized measurements,
and calibration.
* Taiwanese User’s Guide, Option AB0;
Also available as part number 08712-90012.
* Korean User’s Guide, Option AB1;
Also available as part number 08712-90014.
* Chinese User’s Guide, Option AB2;
Also available as part number 08712-90015.
* German User’s Guide, Option ABD;
Also available as part number 08712-90010.
* Spanish User’s Guide, Option ABE;
Also available as part number 08712-90017.
* French User’s Guide, Option ABF;
Also available as part number 08712-90009.
* Japanese User’s Guide, Option ABJ;
Also available as part number 08712-90008.
* Italian User’s Guide, Option ABZ;
Also available as part number 08712-90011.
Warranties
One-year on-site service warranty is standard at no
extra charge. Where on-site service is not available,
one-year return-to-Agilent service is provided.
Customers may convert the standard one-year
on-site warranty to a three-year return-to-Agilent
warranty at the time of purchase.
* Converts one-year on-site warranty to three-year
return-to-Agilent warranty, Option W08
* Two additional years of on-site service, Option W31
Total of 3 years on-site support (where available);
not available with Option W08.
* Four additional years of on-site service, Option W51
Total of 5 years on-site support (where available);
not available with Option W08.
* Commercial calibration certificate with test data,
Option UK6
Can be ordered at time of original purchase.
Measurement Accessories
Accessories are available in these connector types:
3.5 mm, 50 ohm Type-N, BNC, 75 ohm Type-N, and
Type-F. A calibration kit to improve measurement
accuracy is recommended for each type of connector
being measured. A complete line of RF accessories
can be found in the Agilent Microwave Accessories
Catalog, literature number 5091-4269E.
50 Ohm Accessories
* Type-N precision calibration kit, Agilent 85032B
50 ohm Type-N kit includes fixed terminations,
open circuits, and short circuits in both connector
sexes. Recommend deleting the two phasematched
7 mm to Type-N adapters for both connector
sexes female and male.
* Option 001
Deletes 7 mm to Type-N phase-matched adapters
* Type-N economy calibration kit, Agilent 85032E
Standards include fixed termination and opencircuit/
short-circuit combination in Type-N (m) only.
* 3.5 mm precision calibration kit, Agilent 85033D
50 ohm 3.5 mm calibration standards for devices
with 3.5 mm and SMA connectors. Includes
fixed terminations, open circuits and short circuits
in both sexes. Includes two pair of phasematched
7 mm to 3.5 mm adapters for both
sexes. Recommend deleting 7 mm adapters and
ordering 11878A Type-N to 3.5 mm adapter kit.