ZY6288隔热隔音材料耐烧穿试验机
Insulation materials resistant to wear testing machine
一、型号:ZY6288Model: ZY6288
二、符合标准:Conform to the standard:
GB/T25352-2010
美国联邦航空条例FAR25
ZG民航局运输类飞机标准CCAR-25-R4
GB/T25352-2010
The federal aviation regulations FAR25
The civil aviation administration of China transportation aircraft standard CCAR - 25 to R4
三、适用范围:Scope of application:
本标准规定了隔热隔音材料在高强度开放式火焰下的耐烧穿特性的试验方法。
本标准适用于评估隔热隔音材料在高强度开放式火焰下的耐烧穿特性。
This standard stimulates the insulation materials under high strength open flame resistant to burn through the
characteristics of the test method.
This standard applies to the evaluation of insulation materials under high strength open flame burn through
resistance properties.
四、主要性能参数:The main performance parameters:
1、试验室:试验室的地面长度与宽度均不应小于3.05m。
2、燃油导轨可调整,使燃油喷嘴位于距离出口固定片前端8mm的位置。出口固定片应安装在通风管的端部。
3、燃油:燃油宜为JP-8、Jet A或国际上等效的燃油。其流量应为(0.378 0±0.012 6)L/min。如果不能获得该燃油,4、当
燃油标称流量、温度和热流量值符合标准要求时,可采用3号喷气燃料或其他等效的燃油。
5、校准热流计(可共用背面热流计),为总热流密度型、箔式Gardon热流计,量程应为(0~22.7)W/m2,精度为指示读数的
±3%。
6、校准热电偶直径为3.2mm的陶瓷包封、金属护套、接地式K型(镍铬-镍铝)热电偶,其金属丝直径应为0.511mm
7、记录烧穿时间,即火焰穿透试样的时间(如果有)或热流超过2.27W/cm2的时间。
8、设备具有下列安全保护装置:电源超载、 短路保护、控制回路过载保护。
9、采用16位高精度板卡+微机控制,具有结构合理、性能稳定、操作简便等优点;
10、测试期间实时显示测量结果动态地绘出曲线,数据可以保存、调阅和打印输出,可直接打印报表;
1, the laboratory: the laboratory floor length and the width should not be less than 3.05 m.
2, fuel rail can be adjusted, making the fuel nozzle export fixed at the front position of 8 mm. Export stator
should be installed in the ventilation pipe end.
3, fuel oil, fuel oil appropriate for JP - 8, the Jet fuel A or international equivalent. The flow rate shall
be the (0.378 0 + / - 0.012 6) L/min. If you can't get the fuel, 4, when the nominal fuel flow rate,
temperature and heat flow values conform to the requirements of the standards, can use 3 # jet fuel or other
equivalent fuel.
(5, calibration of heat flow meter can be Shared on the back of the heat flow meter), for the total heat flux
density, foil type Gardon heat flux meter, the range should be (0 ~ 22.7 W/m2), plus or minus 3% accuracy for
the indicator reading.
6, calibrating thermocouple diameter of 3.2 mm ceramic coating, metal sheath, grounding type K type
thermocouple (nickel chrome - nickel aluminum), the wire should be 0.511 mm in diameter
7, record burn through time, namely the flame through the sample time (if any) or heat flow more than 2.27
W/cm2.
8, the equipment has the following safety protection device: power overload, short circuit protection, control
circuit overload protection.
9, 16 + microcomputer control, high precision interface card has advantages of reasonable structure, stable
performance, easy operation;
10, during testing real-time display measurement results dynamically draw perfect curve, data can be stored
permanently and read and print output, can be directly printed statement;