ZY6058A日标漏电起痕试验机
Japanese standard tracking testing machine
该试验机采用日本标准JWDS0028《日本配线器具工业会规格》制作。符合JWDS0028、GB2099、VDE0620、GB4706试验标准,用于测量和评定在规定电压下,绝缘体在电场和含杂质水的联合作用时的相比电痕化指数(CTI)和耐电痕(查看供应全新中诺标准的ZY6058A日标漏电起痕试验机的详情)
The machine adopts Japanese standard JWDS0028 Japan's wiring appliances industry will specification production. JWDS0028, GB2099, VDE0620, GB4706 test standard, used to measure and assess under prescribed voltage, insulation in the electric field and the joint effect of impurities in water than electric mark index (CTI) and electric mark (see the ZY6058A day supply of new north standard tracking details of the machine)
主要参数 The main parameters
试验电压电压:100~600V可设定,仪器为数显
Z大试验电流:0.~3A可设定,仪器为数显
滴液装置:
滴液时间间隔可任意设定
滴液次数:1~9999次可任意设定
试验组数:一组、三组、五组,可跟客户需要设计
陶瓷片:共三款,每款五个。
配测力装置
采用PLC编程,整个运行过程都由程序控制。
静电烤漆和镜面不锈钢。
根据客户要求和业务谈定情况而选定
Test voltage voltage: 100 ~ 600 v, can be set for digital display instrument
Biggest test current: 0.5 A ~ 3 A, can be set for digital display instrument
Drip device:
Drip time interval can be set freely
Number of drops: 1 ~ 9999 times can be set freely
Group: a group, three groups, groups of five, but need to design with the client
Ceramic chip: a total of three, five each style.
With load device
PLC programming, the whole operation process is controlled by program.
Electrostatic painting and mirror stainless steel.
According to customer requirements and business conditions and the selected my briefcase