B型热电偶补偿导线BC-FFRP、BC-FF,B型热电偶补偿导线BC-FF46,BCHFF、B型热电偶补偿导线BCHFFR、B型热电偶补偿导线BC-HFFRP、BC-HFFP、BC-HFF46、BC-HFF46R、BCHFF46P、BCHFF46RP、BCHFGP、BCHFGRP、BCHFGR、WC3/25HFF、WC3/25HFFR、B型热电偶补偿导线WC3/25HFFRP、WC3/25HFFP、WC3/25HFF46、WC3/25HFF46R、WC3/25HFF46P、WC3/25HFF46RP、WC3/25HFGP、WC3/25HFGRP,B型热电偶补偿导线BC-FFRP、BC-FF2*1.5
型号 | 使用分类 | 导线温度范围℃ | 热电动势及允差μV | 热电偶测量端温度℃ | 20℃时往复电阻值 ≤Ω/m |
热电势 | 精密度 | 普通级 | 0.5mm2 | 1.0 mm2 | 1.5 mm2 |
SC&RC | G | 0~100 | 646 | ±30(±2.5℃) | ±60(±5.0℃) | 1000 | 0.10 | 0.05 | 0.03 | 0.02 |
H | 0~200 | 1440 | / | ±60(±5.0℃) |
KCA | G | 0~100 | 4095 | ±60(±1.5℃) | ±100(±2.5℃) | 1.40 | 0.70 | 0.47 | 0.28 |
H | 0~200 | 8137 | 900 |
KCB | G | 0~100 | 4095 | 1.04 | 0.52 | 0.35 | 0.21 |
KX | G | -20~100 | 4095 | 2.20 | 1.10 | 0.73 | 0.44 |
H | -25~200 | 8137 |
EX | G | -20~100 | 6137 | ±120(±1.5℃) | ±200(±2.5℃) | 500 | 2.50 | 1.25 | 0.83 | 0.50 |
H | -25~200 | 13419 |
JX | G | -20~100 | 5268 | ±85(±1.5℃) | ±140(±2.5℃) | 1.30 | 0.65 | 0.43 | 0.26 |
H | -25~200 | 10777 |
TX | G | -20~100 | 4277 | ±30(±0.5℃) | ±60(±1.0℃) | 300 | 1.04 | 0.52 | 0.35 | 0.21 |
H | -25~200 | 9285 | ±48(±0.8℃) | ±90(±1.5℃) |
NC | G | 0~100 | 2774 | ±60(±1.5℃) | ±100(±2.5℃) | 900 | 1.50 | 0.75 | 0.50 | 0.30 |
H | 0~200 | 5912 |
NX | G | -20~100 | 2774 | 2.86 | 1.43 | 0.95 | 0.57 |
H | -25~200 | 5912 |
补偿导线其它参数指标
项目 | 单位 | 参数指标 |
PVC绝缘 | PE、XLPE、F46&F绝缘 |
绝缘电阻 | MΩ.km | 25 | 100 |
电压试验 | V/1min | 1000 |
阻燃性能 | 符合GB/T18380-2001阻燃标准中A、B、C类规定。 |
B型热电偶补偿导线BC-FFRP、BC-FF2*1.0,BC-HFF、BC-HFFR、BC-HFFRP、BC-HFFP、BC-HFF46、BC-HFF46R、BC-HFF46P、BC-HFF46RP、BC-HFGP、BC-HFGRP、BC-HFGR、NX-HFF、NX-HFFR、NX-HFFRP、NX-HFFP、NX-HFF46、NX-HFF46R、NX-HFF46P、NX-HFF46RP、NX-HFGP、NX-HFGRP、NX-HFGR,ZR-KC-FGP、ZR-KC-FGRP、ZR-KC-FGP2、ZR-KC-FGR、ZR-KC-FGPR、ZR-BC-FGVP、ZR-BC-FGRP、ZR-BC-FGP2、ZR-BC-FGR、ZR-BC-FGPR、ZR-NC-FGP、ZR-NC-FGRP、ZR-NC-FGP2