供应Rosemount(罗斯蒙特)5300系列超高性能导波雷达液位与界面变送器•通过直接切换技术提供业界领先的测量能力和可靠性•利用高级诊断和PlantWeb®功能提高设备利用率•更高的安全性和FMEDA测试适合于SFF>90%的SIL2应用•通过坚固耐用的模块化设计节省成本并提高安全性•采用多变量™变送器可减少仪表数目和过程开孔•凭借超高性能和精度提高生产能力和产品质量•通过强大易用的组态工具和无缝的工厂集成能力降低开车成本•通过智能电流接口提高电磁兼容性和安全性•利用预测性维护和便捷的故障诊断能力节省运营开支Rosemount(罗斯蒙特)5300系列导波雷达液位与界面变送器的特性经过优化,以适应更多应用•适合于大多数液位和固体料位应用,以及液体界面应用•创新性设计,能够可靠处理复杂的应用,包括过程容器、控制和安全要求•有各种材料、过程连接件、导波杆型式和附件可供选择•有多种选件,可实现与现有旁通管的配合,或者利用罗斯蒙特9901高品质旁通管实现整体解决方案•动态蒸汽补偿(DVC)功能可对蒸汽空间介电常数的变化自动进行补偿Rosemount(罗斯蒙特)5300系列功能规格
Product | Model 5301 for level of liquids or submerged interfaces. Model 5302 for level and interface in liquids. Model 5303 for level of solids. |
Measurement Principle | Time Domain Reflectometry (TDR) |
Measuring Range | Up to 164 ft. (50 m) |
Dielectric Constant | Minimum 1.2 for coaxial probe or single probe installed in bypass, |
Probe Materials | SST, Alloy 400, Alloy C276 (UNS N10276), or PTFE-covered SST |
Reference Accuracy | ± 0.1 in. (± 3 mm) or ± 0.03% of measured distance, whichever is greatest |
Repeatability | ±0.04 in. (±1 mm) |
Output | 4-20mA with superimposed digital HART® communication FOUNDATION® Fieldbus Modbus |
Process Temperature | Up to 752 ºF (400 ºC). |
Lowest Temperature | From -320 ºF (-196 ºC) |
Process Pressure | 4-20mA with superimposed digital HART® communication, and FOUNDATION® Fieldbus |
Ex-Approvals | Intrinsic Safety (IS) or Explosion-proof/Flameproof (ATEX, CSA, IECEx, FM, ...) |
Display | 5-digit integral display (Optional) |
Output Variables | Level, Interface Level, Distance, Interface Distance, Upper Product Thickness, Volume, Level Rate, Signal Strength, Housing Internal Temperature, Aout current and % of Range |
Enclosure | Polyurethane-covered die-cast Aluminum or stainless steelhousing with dual compartments. |
Ingress Protection | Type 4X, IP66, IP67 |
Fieldbus Functionality | Link-master device (backup LAS), PlantWeb Alerts, Methods |
Fieldbus Blocks | Resource, 3xTransducer, 6xAnalog Input (30 ms), PID (40 ms), Arithmetic, Input Selector, Output selector (65 ms) ,Signal Characterizer (75 ms) |
Configuration Tools | Rosemount Radar Master, 475 Field Communicator, AMS Suite: Intelligent Device Manager, DeltaV or any other DD- or EDDL-compatible host-system. |