DGMX2-3-PP-CW-B-40/伊顿-VICKERS减压阀
Low Flow Pressure Compensation (Minimum to 69 bar (1000 psi) valve pressure drop)
Model Flow cm3/min (in3/min) Typical Variation (%) Maximum Variation (%)
Flow Variation with Temperature, 27C to 66C (80F to 150F)
Flow cm3/min (in3/min) Average Variation (%) Maximum Variation (%)
Over Speed Control (–S10)
The flow control hydrostat under zero
flow conditions is spring offset to its full
open position. This permits an initial flow
greater than the throttle setting, and
may result in a momentary over speed
at the start of the feed cycle.
DG4V-03-6* 设计, DG4V-3S 流量至 40 l/min (10.5 USgpm), 6* 设计
, 电磁方向控制阀, DG4V-3 流量至 80 l/min (21
USgpm), ISO 4401, 规格 03; ANSI/B93.7M-D03 样本 中文
电磁控制阀 ASI 连接开关, 用于额定电流为 2A 额定电压为
24V DC (8 至 38W) DIN 43650 线圈连接可安装在
单或双电磁控制阀上 数据表 English 01-05-519-EN-0800
DG4V-3S, EN 490 用于工程机械设备, 流量至 40 l/min (10
.5 USgpm), 6* 设计, P, A & B 压力至 350 bar (5000 psi), T 压力至 210 bar (3000 psi)
If this condition causes a problem in
your application, it can be greatly
reduced with the over speed control
Adjust the hydrostat as follows:
1. Back out the adjusting screw and
operate the system in the feed mode.
Adjust the throttle setting to the desired
2. Turn in the adjusting screw until the
feed rate drops, then back out the
adjusting screw just enough to restore
the original feed rate. The screw will
remain in this position.
DGMX2-3-PP-CW-B-40/伊顿-VICKERS减压阀