数字式万用表 KEW 1011A/1012A6000计数,条形图显示。真有效值显示(1012A)。温度测试(1011A)。MAX/MIN功能。数据保持功能。比较测试功能。电池电压警告与自动关机功能(操作完成15分钟后)。自动量程与手动量程(量程保留)。设计符合国际安全规格IEC61010-1CAT.III300V/CAT.II600V。数字式万用表 KEW 1011A/1012A
| KEW 1011C | KEW 1012C |
直流电压 | 600.0mV/6.000/60.00/600.0/600V(输入电阻:10MΩ) ±0.5%rdg±2dgt(600.0mV/6.000/60.00/600.0V) ±0.8%rdg±3dgt(600V) |
交流电压 | 6.000/60.00/600.0/600V(输入电阻:10MΩ) |
±1.0%rdg±3dgt(6.000/60.00/600.0V) ±1.5%rdg±3dgt(600V) | ±1.5%rdg±5dgt (6.000V) ±1.2%rdg±3dgt (60.00/600.0V) ±1.5%rdg±5dgt (600V) |
直流电流 | 600.0/6000μA/60.00/600.0mA/6.000/10.00A ±1.2%rdg±3dgt (600.0/6000μA/60.00/600.0mA) ±2.0%rdg±5dgt (6.000/10.00A) |
交流电流 | 600.0/6000μA/60.00/600.0mA/6.000/10.00A ±1.5%rdg±4dgt (600.0/6000μA/60.00/600.0mA) ±2.2%rdg±5dgt (6.000/10.00A) |
电阻 | 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ ±1.0%rdg±2dgt (600.0Ω/6/60.00/600.0kΩ/6.000MΩ) ±2.0%rdg±3dgt (60.00MΩ) |
频率 | 10/100/1000Hz/10/100/1000kHz/10MHz ±0.1%rdg±5dgt (输入电流:800μA/电压:1.5V/Hz:0.4V以上[~10kHz]) |
二极管 | 2.8V释放电压:约0.4mA测试电流 |
电容 | 40nF/400nF/4μF/40μF/400μF/4000μF |
温度 | -50~+700℃(使用温度探棒时+300℃) |
导通 | 0~600Ω (低于100Ω时蜂鸣) |
耐电压 | 3700V AC /分钟 |
安全规格 | IEC 61010-1 CAT.III 300V/CAT.II 600V污染度2 IEC 61010-2-031 IEC 61326-1 |
电源 | 单3干电池R6P(1.5V)×2 |
外形尺寸 | 161(L)×82(W)×50(D)mm |
重量 | 约280g(含电池,软套) |
附件 | KTL04(测试线)单3干电池R6Px 2 8216(K型温度探棒-1011A)使用说明书 |