Physical Properties of the B201 Sensor Thickness: 0.008" (0.203 mm) Length: 9.0" (228.6 mm) End-to-end Width: 0.55" (14 mm) Active sensing area: 0.375" (9.53 mm) Diameter Connector: Custom interface toELFData Acquisition System Recommended Maximum ForceSensor | Max. Force | Max. Force | | (High Gain) | (Low Gain) | SensorMax. ForceMax. Force B201 - L | 0 - 1 lb (4.4 N) | 0 - 25 lb (111 N) | B201 - M | 0 - 25 lb (111 N) | 0 - 150 lb (667 N) | B201 - H | 0 - 150 lb (667 N) | 1 - 1000 lb (4448 N) |
(Adjustable gain feature of theELFSystem allows you to set force ranges)
Typical PerformanceLinearity (Error): < ±3% (Line drawn from 0 to 50% load) Repeatability: < ±2.5% of Full Scale (Conditioned Sensor, 80% of Full Force Applied) Hysteresis: < 4.5 % of Full Scale (Conditioned Sensor, 80% of Full Force Applied) Drift: <5% / logarithmic time (Constant Load of 90% sensor rating) Response Time: < 5 µsec (Time required for the sensor to respond to an input force; Impact load - recorded on Oscilloscope) Operating Temperature: 15°F - 140°F (-9°C - 60°C)* * Force reading change per degree of temperature change = ±0.2% / °F (0.36%/°C) * For loads less than 10 lb, the operating temperature can be increased to 165° F (74° C) |