【Mini Redundant】MRW-6400P400W Server ,Workstation ,Storage System ,IPC
185x15086(mm)
7.28x5.91x3.39(inch)
VOLTAGE: 90 ~ 264 VAC FULL RANGE
Output VoltageTD | Output Current Min. | Output Current Max. | Regulation Load | Regulation Line | Output Ripple & Noise Max.[P-P] |
5V | 3 | 35 | ± 5% | ± 1% | 50mV |
12V | 2 | 28 | ± 6% | ± 1% | 120mV |
-5V | 0 | 0.5 | ±10% | ± 1% | 150mV |
-12V | 0 | 1.2 | ±10% | ± 1% | 150mV |
3.3V | 1 | 25 | ± 5% | ± 1% | 50mV |
+5VSB | 0.1 | 2 | ± 5% | ± 1% | 60mV |
REMARKS: * NEITHER +5V & + 3.3V NOR +3.3V & 12V SHOULD EXCEED 48 A * TOTAL MAXIMUM OUTPUT OF 5V, 3.3V AND 12V : 378W
*Active PFC (full range), MEET IEC-1000-3-2 CLASS D
*12V Max. Current : 28A
*TEMPERATURE RANGE : OPERATING 0℃ ~ 40℃, STORAGE –20℃ ~ 70℃
* HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
* REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
*EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
*SAFETY: UL 1950, CSA 22.2 NO/ 950, TUV IEC 950
*HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION
*Cooling : TWO 40 mm DC FANS (MODULE)
*AC INLET IN EACH MODULE
*Serial ATA optional
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.