MODEL | 7110 |
AC WITHSTANDVOLTAGE |
Output Rating | 5KVAC/12mA |
Range | Resolution | Accuracy |
Output Voltage,KVAC | 0-5.00 | 0.01 | ±(2% of setting +5V) |
Output Frequency | 50Hz/60Hz ±100ppm, UserSelection |
Output Waveform | Sine Wave ,THD.<2%(Resistive Load), Crest Factor = 1.3 - 1.5 |
Output Regulation | ± (1% of output + 5V), From noload to full load |
SETTINGS |
Hi-Limit AC Current,mA | 0.10 - 12.00 | 0.01 | ±(2% of setting +2counts) |
Lo-Limit AC Current,mA | 0.00 - 12.00 | 0.01 | ±(2% of setting +2counts) |
Ramp Time, second | 0.1 - 999.9 | 0.1 | ±(0.1% +0.05sec) |
Dwell Time, second | 0, 0.2 - 999.9(0=continuous) | 0.1 |
Arc Detection | 0, 1 - 9 ranges (0=OFF, 9 isthe most sensitivity) |
MEASUREMENT |
AC/DC Voltage, KV | 0 - 6.00 | 0.01 | ±(1.5% of reading +1count) |
DC Voltage, KV (IRonly) | 0.10 - 1.00 | 0.01 | ±(1.5% of reading +3V) |
AC Current, mA | 0.10 - 12.00 | 0.01 | ±(2% of reading +2counts) |
DC Current, mA | 0.02 - 5.00 | 0.01 | ±(2% of reading +2counts) |
Resistance, MΩ | 1 - 1000(Auto Range) | 0.001 | ±(3% of reading+2counts) at > 500VDC±(7% of reading +2counts) at <500VDC |
0.01 0.1 |
GENERAL |
Input Voltage AC | 115/230Vac±15%, 50/60Hz ± 5%,Fuse 3.1 Fast |
PLC Remote Control | Input : Test ,Reset |
Output : Pass , Fail ,Processing |
Memory | 5 Sets Store/Recall of eachMemory, 4 Test Mode Selectable (W, I, W~I, I~W Only 7112, 7122) |
Display | 16×2 LCD with backlight |
Key Lock | To prevent unauthorizedalteration of the test Parameters |
Calibration | Build-in software and externalcalibrated meters |
Environment | 0-40℃, 20-80%RH |
Dimension/NetWeight | 280mm(W)×89mm(H)×370mm(D)/9Kg |
STANDARDACCESSORIES |
Power Cord(10A) | ×1 |
Fuses | ×3 (Including a spare containedin the fuse holder) |
Hipot Test Lead,1.5m(1101) | ×1 |
Hipot Return Lead,1.8m(1102) | ×1 |