COMPLIANCE STANDARD | EN 60079-0, EN 60079-1, EN 60079-7, EN 61241-0, EN 61241-1, IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 61241-0 & IEC 61241-1 |  |
CERTIFICATION | 



 |
CERTIFICATE | SIRA 01ATEX1272X - Ex Notified Body No. 0518 POCC GB MJL14.B00030 CSA 1356011 IECEx SIR 07.0096X NEPSI GYJ06186X |
GLAND MARKING | MJL14 Peppers GU15 3BT UK A2LDSF/20/M20 CA Sira 01ATEX1272X Ex II 2 GD EExd IIC/EExe II IEC Ex SIR 07.0096X Exd IIC/Exe II/Ex tD A21 IP68 |
APPLICATION | EExd Equipment | A2LDSF type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2 | Gas Group | Internal Ignition Source | Enclosure Volume | Which Zone | Use A2L**F Gland | IIC, IIB, IIA | NO | Any | Zone 1 or 2 | YES | IIB, IIA | YES | Any | Zone 2 | YES | IIB, IIA | YES | 2 litres or less | Zone 1 | YES | EExe Equipment | Other Equipment | Gas Group II, Zones 1 and 2 | Ignitable Dust, Zones 21 and 22 |
|
INGRESS PROTECTION | IP66 and IP68 @ 25 metres, Enclosure Type 4X |
MATERIALS | Brass CZ121 ((A2LDSF) 316 Stainless Steel (A2LDSSF) Aluminium Alloy (A2LDSAF)
Outer sheath seal material: Standard (A2LDSF) Neoprene, black. Option (A3LDSF) Silicone, white. Integral entry thread seal: Nitrile is supplied with neoprene outer seal version. Silicone is supplied with silicone outer seal version. |
VARIATIONS | For lead sheath cables the gland is fitted with a metallic continuity washer: Brass (A4LDSF); 316 Stainless Steel (A4LDSSF) |
OPTIONS | THREADS | ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG |
SEALS | Extended operating temperature -60°C to +180°C, halogen free versions: Brass (A3LDSF); 316 Stainless Steel (A3LDSSF); Aluminium (A3LDSAF) |
PLATING | Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN) |
OPERATING TEMPERATURES | Standard Seals -20ºC to +85ºC Silicone Seals - 60ºC to +180ºC |
ACCESSORIES | Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN); Aluminium (ACALN) Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET); Aluminium (ACAET) IP Washer - Nylon (ACNSW); Red Fibre (ACFSW) Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW) Shroud - PVC (ACSPVC); PCP (ACSPCP); Low Smoke Zero Halogen (ACSSIO) |
EXAMPLE PART NUMBER | Sample: A2LDSF /ZP/20S/M20 A2LDSF: A*LDSF - Gland type and body material (Brass) *2**** - Seal material (Neoprene) ZP - Zinc plating 20s - Gland size with regards to cable acceptance range M20 - Entry thread |
Gland Size | Entry Threads | Metric | NPT/BSP |
| Entry Thread Length [B] | Max Across Corners [A] | Max Protrusion Length | Gland Seal Range Cable Outer Sheath [D] | Min | Max |
| Shroud Size |
|
16 | M20 | 1/2" or 3/4" | 16 | 28.0 | 66.0 | 4.0 | 8.4 | L24 | 20s | M20 | 1/2" or 3/4" | 16 | 28.0 | 66.0 | 7.2 | 11.7 | L24 | 20 | M20 | 1/2" or 3/4" | 16 | 29.7 | 66.0 | 9.6 | 14.0 | L27 | 25 | M25 | 3/4" or 1" | 16 | 39.6 | 66.0 | 13.5 | 20.0 | L36 | 32 | M32 | 1" or 1*1/4" | 16 | 45.1 | 66.0 | 19.5 | 26.3 | L41 | 40 | M40 | 1*1/4" or 1*1/2" | 16 | 55.9 | 74.0 | 23.0 | 32.2 | L51 | 50s | M50 | 1*1/2" or 2" | 16 | 71.5 | 74.0 | 28.2 | 38.2 | L65 | 50 | M50 | 2” | 16 | 71.5 | 74.0 | 33.2 | 44.1 | L65 | 63s | M63 | 2" or 2*1/2" | 19 | 88.0 | 74.0 | 39.3 | 50.1 | L80 | 63 | M63 | 2*1/2" | 19 | 88.0 | 74.0 | 46.7 | 56.0 | L80 | 75s | M75 | 2*1/2" or 3" | 19 | 99.0 | 74.0 | 52.3 | 62.0 | L90 | 75 | M75 | 3” | 19 | 99.0 | 74.0 | 58.1 | 68.0 | L90 | 80 | M80 x 2 | 3" or 3*1/2" | 25 | 115.2 | 100.0 | 62.3 | 72.0 | L104 | 85 | M85 x 2 | 3" or 3*1/2" | 25 | 115.2 | 100.0 | 69.1 | 78.0 | L104 | 90 | M90 x 2 | 3*1/2" or 4" | 25 | 125.7 | 1050.0 | 74.1 | 84.0 | L114 | 100 | M100 x 2 | 3*1/2" or 4" | 25 | 125.7 | 100.0 | 82.0 | 90.0 | L114 | All Dimensions are in Millimetres | NOTES:- Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting
- Gland Size does not necessarily equate to the entry thread size
- Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required
- Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions
- Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
- For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads
- Where A2LF type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system
- The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/ installation
- Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full
- In order to maintain an IP rating greater than IP54, when used in a clearance hole, a suitable IP washer is required.
- Peppers supplies cable glands with parallel entry threads which conform to the flameproof threaded joint requirements of IEC 60079-1 and other equivalent standards. They usually incorporate a thread run out according to the available machining techniques, and will not have a full-form thread for the entire length. Peppers will not be held responsible for clients’ installations where this has not been taken into account.
|
|